2 typical trouble shooting – PowerWalker VFI 1000 LE User Manual

Page 28

Advertising
background image

- 28 -

4.2 Typical Trouble Shooting

(1) Trouble shooting according to warning indication.

LED

Possible cause

Action

1-3

4

5

6

□

★

□

★

Fan abnormal, or

internal temperature is

too high

Check the fans. Check the loads.

Check the ventilation, ambient

temperature.

□

□

□

★

I/P fuse open

Check the I/P fuse and related

power component.

□

★

□

☆

Battery low abnormally

or battery not connected

(line mode), or battery

discharged over 14

hours

Check the battery. If the UPS is

a long back up model, check

whether the external battery

protection (breaker of fuse) is

open. If the battery is damaged

or aged, replace the battery.

□

□

□

☆

Battery over voltage, or

charger failed

Check the charger output,

battery input.

□

: Depended on the original display

☆

: Flash every 4 seconds

★

: Flash every second

Note 1: when the UPS warning, the red Fault/Warning LED will flash, and the

buzzer will beep once every second.

Note 2: When the UPS warning, the UPS is still working on the original mode

with the original display except the inverter LED maybe flash.

Note 3: If the warning can’t be shoot, please contact the distributor or service

center.