Warning, Ao p v, Av o – Peerless-AV PLAV70-UNLP-GB - Installation User Manual

Page 6: 1installation to concrete wall

Advertising
background image

6 of 14

ISSUED: 11-21-06 SHEET #: 202-9180-7 06-14-12

Use wall plate (A), making sure that it is level, as
a template to mark holes. The top mounting slots
should be located .43" below the desired screen
center. Use the masonry bit to drill 5/16" (8 mm)
dia. holes to a minimum depth of 3" (76 mm). Insert
anchors (V) in holes fl ush with wall as shown (right).
Place wall plate (A) over anchors (V) and secure
with 5/16 x 3" wood screws (O) and washers (P).

1

Installation to Concrete Wall

A

O

P

V

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete

thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a
solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90
specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Make sure that the supporting surface will safely support the combined load of the equipment and all attached

hardware and components.

WARNING

• Tighten wood screws so that wall plate is fi rmly at-

tached, but do not overtighten. Overtightening can
damage screws, greatly reducing their holding power.

• Never tighten in excess of 80 in • lb (9 N.M.).

WARNING

• Always attach concrete expansion anchors directly

to load-bearing concrete.

• Never attach concrete expansion anchors to con-

crete covered with plaster, drywall, or other fi nishing
material. If mounting to concrete surfaces covered
with a fi nishing surface is unavoidable, the fi nishing
surface must be counterbored as shown below. If
plaster/drywall is thicker than 5/8", custom fasteners
must be supplied by installer (not UL evaluated).

WARNING

1

3

2

V

Drill holes and insert anchors (V).

Place plate (A) over anchors (V) and secure with screws (O).

Tighten all fasteners.

A

V

O

concrete
surface

CUT

A

W

A

Y

VIEW

INCORRECT

CORRECT

wall

plate

wall

plate

plaster/
dry wall

plaster/
dry wall

concrete

concrete

Advertising