Warning, Ae d, Installation to solid concrete or cinder block 1 – Peerless-AV PT630 - Installation User Manual

Page 5

Advertising
background image

5 of 34

ISSUED: 11-19-07 SHEET #: 202-9245-2 07-28-09

Make sure that wall plate (

A) is level, use it as a

template to mark two mounting holes. Drill two 5/16"

(8 mm) dia. holes to a minimum depth of 2.5"

(64 mm). Insert anchors (

E) in holes flush with wall

as shown. Place wall plate over anchors and secure

with two #14 x 2.5" screws (

D). Level, then tighten all

fasteners.

Installation to Solid Concrete or Cinder Block

1

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual

concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount

in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet

ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole

instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-

ware and components.

WARNING

D

CINDER

BLOCK

SOLID

CONCRETE

A

E

1

3

2

E

Drill holes and insert anchors (

E).

Place plate (

A) over anchors (D) and secure with screws (E).

Tighten all fasteners.

A

E

D

concrete

surface

CUT

AW

AY

VIEW

INCORRECT

CORRECT

wall

plate

wall

plate

plaster/

dry wall

plaster/

dry wall

concrete

concrete

• Tighten screws so that wall plate is firmly attached,

but do not overtighten. Overtightening can damage

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly

to load-bearing concrete.

• Never attach concrete expansion anchors to

concrete covered with plaster, drywall, or other

finishing material. If mounting to concrete surfaces

covered with a finishing surface is unavoidable,

the finishing surface must be counterbored as

shown below. Be sure concrete anchors do not

pull away from concrete when tightening screws.

If plaster/drywall is thicker than 5/8" (16 mm),

custom fasteners must be supplied by installer (not

evaluated by UL).

WARNING