ISSUED: 06-15-09 SHEET #: 145-9008-4 01-24-12
Using access plate (B) as a template, drill six 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach
access plate (B) to centers of wood studs using six #14 x 2.5" wood screws (H) shown.
Installation to Wood Stud Wall
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is
highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers
are responsible to provide hardware for other types of mounting situations.
WARNING
1
H
B