Operating parameters, Instrumentation, Materials of construction – GE P&W SeaPRO Series 50 Hz, 35,000 ppm NaCL 500-1500 m3_day (100-300 gpm) User Manual

Page 2: Options available, Documentation included, Seapro models

Advertising
background image

Page 2

FS1016EN

Operating Parameters

Design Feed TDS

35,000 ppm NaCl

Maximum Recovery

45%

Nominal Rejection

95-98%

Operating Temperature

1.6 to 29.4ºC (35 to
85ºF)

Minimum Inlet Pressure

2 Bar (30 psig)

Design Temperature

25ºC (77ºF)

Instrumentation

Flow Meters ................... Permeate, concentrate, low

pressure (LP) ERD inlet, high
pressure (HP) ERD outlet

Conductivity .................. Permeate
pH ...................................... Feed
Pressure .......................... Pre-filter, post-filter, primary,

final, permeate, concentrate,
LP ERD inlet, LP ERD outlet,
HP ERD inlet, HP ERD outlet
(PRE Feature= Primary, Final
transmitter)

Pressure Switches ...... Feed, permeate, concen-

trate, primary

Instrument Center ..... Thornton 770 MAX

Materials of Construction

Frame

Painted Carbon Steel

Cartridge Filter

RO.Zs 05-40, 5-micron nomi-
nal

Cartridge Filter Housing

GRP (glass reinforced plastic)

Membrane Elements

AD-440

Membrane Housing

FRP

Low Pressure Pipe

Schedule 80 PVC

High Pressure Pipe

Duplex 2205

Enclosures

NEMA 4

Options Available

Allen Bradley control system

Multi-Media filters

Clean-in-Place (CIP) units

Chemical feed systems

Transfer pumps and storage tanks

Documentation Included

Operation and maintenance manual

Control narrative

Drawings: piping and instrumentation, electri-
cal and general dimensional

SeaPRO Models

MODEL

SeaPRO-42

SeaPRO-63

SeaPRO-84

SeaPRO-126

Permeate rate:
Concentrate Rate:
Feed Rate:

550 m

3

/day (100 gpm)

672 m

3

/day (122 gpm)

1,222 m

3

/day (222 gpm)

825 m

3

/day (150 gpm)

1,008 m

3

/day (183 gpm)

1,833 m

3

/day (333 gpm)

1,100 m

3

/day (200 gpm)

1,344 m

3

/day (224 gpm)

2,444 m

3

/day (444 gpm)

1,650 m

3

/day (300 gpm)

2,017 m

3

/day (367 gpm)

3,667 m

3

/day (667 gpm)

Pumps and Motors

Manufacturer:
Quantity:
HP Pump HP and Type:
Boost Pump HP and Type:

Fedco

2

75 kW (100 Hp) TEFC

5.6 kW (7.5 Hp) TEFC

Fedco

2

110 kW (150 Hp) TEFC

7.5 kW (10 Hp) TEFC

Fedco

2

150 kW (200 Hp) TEFC

15 kW (20 Hp) TEFC

Fedco

2

186 kW (250 Hp) TEFC

15 kW (20 Hp) TEFC

Energy Recovery Booster

Model:
Manufacturer:
Quantity:

PX-140S

ERI

1

PX-220

ERI

1

PX-140S

ERI

2

PX-140S

ERI

3

Membrane Elements and Housings

Membranes Quantity:
Memb. Housing Style:
Banking Arrangement:

42

7 element long, 4 port

6, parallel

63

7 element long, 4 port

9, parallel

84

7 element long, 4 port

12, parallel

126

7 element long, 4 port

18, parallel

Cartridge Filtration

Cartridge Filter:
Filter Length:
Filter Quantity:

RO.Zs05-40

40” (102 cm)

22 per change out

RO.Zs051-40

40” (102 cm)

54 per change out

RO.Zs05-40

40” (102 cm)

54 per change out

RO.Zs05-40

40” (102 cm)

108 per change out

Advertising