Additional information – GE P&W Pleated Filters - Flotrex HR Pleated Filters User Manual

Page 2

Advertising
background image

Page 2

FS1091EN Jul-08

Table 2: Dimensions

Nominal O.D.

Nominal I.D.

Effective Filtration Area

2.75” (70 mm)

1.25” (31 mm)

8.0 ft

2

(0.74 m

2

)

Table 3: Operational Limits

Description

Operational Limits

Maximum Forward Differential
Pressure

60 psi (4.1 bar) at 70ºF (21ºC)

Maximum Reverse Differential
Pressure

30 psi (2.1 bar) at 70ºF (21ºC)

Maximum Operating Temperature

180ºF (82ºC) at 10 psid (0.69 bar) in
water

Table 4: Flow Performance in Clean Water

1

1

Data based on 10” length filter

Additional Information

• Flotrex-HR filters may be sanitized with com-

patible chemical agents such as ozonated
water. The filters must not be autoclaved or
steam sterilized.

• Flotrex-HR filters meet the test criteria for

USP24 class VI-121°C plastics and pass the
MEM Elution Cytotoxicity Test.

• Aqueous extracts from Flotrex-HR filters con-

tains less than 0.25 EU/ml. The filters typically
exhibit low levels of non-volatile residues. FHR
filters are ozone tolerant for 9,000 ppm/hr with
no extractables.

• Table 5 provides more information on ordering

Flotrex HR filters.

10 µm

25 µm

Table 5: Ordering Information

Type

Absolute

Micron Rating

Nominal

Cartridge Length

End #1

Adapter

End #2

Adapter

Elastomer

Material

FHR

03 = 3.0 µm

1 = 10 in (25 cm)

A = Open End Gasket

A = Open End Gasket

V = Viton

2

10 = 10 µm

4

2 = 20 in (51 cm)

E = 222 O-Ring

G = Closed End Cap

T = Teflon

2

25 = 25 µm

3 = 30 in (76 cm)

F = 226 O-Ring

H = Fin Adapter

Encapsulated Viton

4 = 40 in (102 cm)

2

Viton and Teflon are registered trademarks of DuPont.

Advertising