E4H Series 60 Hz

Reverse Osmosis Machine 15,200 to 43,200 gallons per day

Figure 1: E4H Series 60 Hz

When you mention reverse osmosis (RO), GE Water
& Process Technologies is the first name to come to
mind. Our E-series RO machines (Figure 1) are de-
signed for durable operation, high quality product
water production, easy installation and straightforward
control.

General Properties

Typical Applications

Process ingredient water

Safe drinking water

Boiler feed water

Ion exchange pre-treatment

Standard Economy Features

5-micron pre-filter and housing, 20” (50.80 cm)

Automatic inlet shutoff valve

Motor thermal protection

Pre/Post-filter and primary/final pressure
gauges

Permeate and concentrate flow rotameters

Permeate conductivity meter

ALARMS: Low inlet pressure, high amp draw

Feed water flush on shut down

Deluxe (DLX) Features – In addition to ECN
Features

AccuTrak* RO microprocessor controller

SD card for collection of operating data

Permeate and concentrate paddlewheel flow
sensors

Inlet pH sensor

Permeate tank level monitoring

Chemical dosing pump for antiscalant dosing or
pH adjustment

Clean in Place (CIP) system, 5 HP (3.7 KW)

ALARMS: Low inlet pressure, high concentrate
and permeate pressure, high temperature, high
permeate conductivity, high/low pH, motor
fault, and fill-time exceeded

Table 1: Operating Parameters

Operating Pressure

220 psig (15 bar)

Maximum Recovery

75%

Nominal Rejection

95-98%

Operating Temperature

55-85

F (13-30

C)

Minimum Inlet Pressure

30 psig (2 bar)

Design Temperature

77

F (25

C)