GE P&W Spiral Wound Membranes - MUNI RO LE Series User Manual
Page 2

Page 2
FS1275EN
Figure 2: Element Dimensions Diagram – Female
Table 2: Dimensions and Weight
Model
1
Dimensions, inches
(cm)
Boxed
A
B
2
C
3
Weight
lbs (kg)
MUNI-RO-400-LE
40.0
(101.6)
1.125
(2.86)
7.9
(20.1)
35
(16)
1
These elements are bagged wet before shipping.
2
Internal diameter.
3
The element diameter (dimension C) is designed for optimum performance in GE
pressure vessels. Others pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters
Typical Operating Pres-
sure
110psi (758kPa)
Typical Operating Flux
10-20GFD (15-35LMH)
Maximum Operating
Pressure
400psi (2,758kPa)
Maximum Temperature
Continuous operation: 112°F
(50°C)
Clean-In-Place (CIP): 112°F (50°C)
Minimum Crossflow
30gpm (6.8m3/h)
pH Range
Continuous operation: 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5
Maximum Pressure Drop Over an element: 12psi (83kPa)
Per housing: 50psi (345kPa)
Chlorine Tolerance
1,000+ ppm-hours,
dechlorination recommended,
Feedwater
NTU < 1
SDI < 5
Recommended single el-
ement recovery
< 15 %