MAX Power CT80-IP Electric Tunnel Thruster User Manual

Page 7

Advertising
background image

Manual CT60-IP & CT80-IP

April 2009

www.max-power.com

6

It is essential to install a manual battery isolator and if possible an electric

battery isolator at the base of the thruster motor power line.
When using a manual battery isolator it must be visible, clearly marked & easily
accessible.

Thruster motor power supply:
These values are given as an indication, assuming that the batteries are charged at
100% and in charge, that is either 13.8V or 25.4V.

The performance data of the CT60-IP / CT80-IP is measured with an approx.
consumption of 400A and 11V (12V) or 280A and 22V (24V) at the motor’s connections.

Please refer to the characteristics given by the manufacturer of the batteries that will be
used (see section 9 “Batteries”).

Power wiring:
Measure the shortest and most direct route possible between the battery(ies) and the
electric motor; remembering to allow for both “positive and negative” cables.

Recommended cable sections:

Cable lengths

CT60-IP / CT80-IP 12V

CT60-IP / CT80-IP 24V

L

5 m (2,5 x 2)

50mm²

35mm²

5< L

10 m (5 x 2)

70mm²

50mm²

10 < L

15 m (7,5 x 2)

95mm²

70mm²

15< L

20 m (10 x 2)

120mm²

95mm²

For all connections, use appropriate terminals for the cable sections chosen.
It is possible to reduce the cable section to facilitate easy connection but only over a
short distance.
In this case, appropriated crimp fittings should be used at the
connections.
Please consult the "Electrical installation" diagram p. 11 for more information


8. MAIN POWER FUSE

Fuse sizes for overcurrent protection are to be determined on the basis of the cable
sections in the circuit and NOT the amperage drawn by the appliance (thruster motor) in
the circuit.

Thruster

Maximum Amperage

Max Power Fuse size

CT60-IP / 12V

330A

160A

CT60-IP / 24V

180A

125A

CT80-IP / 12V

360A

200A

CT80-IP / 24V

200A

125A

9. BATTERIES

Thrusters are high amperage consumers with instantaneous demands, thus, we
recommend you use maintenance-free “starting” type batteries, with high CCA outputs.

Example:
Battery: Exide Maxxima900 12V
Capacity: 55 Ah
CCA: 800

Thruster

Batteries number

CT60-IP & CT 80-IP 12 V

2 serials

CT60-IP & CT 80-IP 24 V

2 parallels