Prokit's Industries MT-5210 User Manual
Page 3
Advertising

3
4. CHARACTERISTIC
1
GENERAL
1-1
Displaying: LCD displaying.
1-2
Max. displaying: 1999
3 1/2 digit
auto polarity indication.
1-3
Measuring method: dual slope A/D conversion.
1-4
Sampling rate: approx. 3 times/second.
1-5
Over range indication: the MSD displays“1”.
1-6
Low battery indication:“
” appears.
1-7
Operation environment:
0
40 ℃
R.H.<80% .
1-8
Power
9V×1 NEDA1604/6F22 or equivalent model
.
1-9
Size:189Ч97Ч35mm
1-10 Weight: approx. 362g
without battery
.
1-11. Accessory: operation manual, gift box, test leads
2
TECHNICAL CHARACTERISTIC
Accuracy:±(a%× rdg d) at (23±5)℃
R.H.<75%
2-1. Inductance (L)
RANGE
ACCURACY
RESOLUTION
MEASURE
FREQUENCY
2mH
1uH
20mH
10 uH
200mH
±(2.0%+5d)
100uH
2H
±(5.0%+5d)
1mH
20H
±(5.0%+15d)
10mH
About 200Hz
1H=10³mH=10
6
uH
Advertising