Prokit's Industries MT-5110 User Manual
Page 4

2-2. ELECTRICAL SPECIFICATION
Accuracy is ±(percentage of reading + number of digit) at 23±5
℃
,<80%RH.
Range Accuracy Resolution
Test
Frequency
Max indication
value
200pF ±(0.5%+7) 0.1pF
800Hz
199.9pF
2nF 1pF
800Hz
1.999nF
20nF 10pF
800Hz
19.99nF
200nF 100pF
800Hz
199.9nF
2uF 1000pF
800Hz
1.999uF
20uF 0.01uF
80Hz
19.99uF
200uF
±(0.5%+5)
0.1uF 8Hz 199.9uF
2000uF ±(2%+5)
1uF
8Hz
1999uF
20000uF ±(3%+10)
10uF
8Hz
1999(×10)uF
pF= Pico Farad(10
-12
F ),nF= nan Farad(10
-9
F). uF= micro Farad(10
-6
F)
Excitative voltage: Max.2.8Vrms
Overload Rating: Protection by a 0.1A/250V fuse.
3. OPERATION PANEL
1. Model Number
2. LCD display: display the test value and unit.
3. Backlight key: press the button lightly; it
was turning off by itself about 8 seconds.
4. Capacitance “+”input terminal.
5. Capacitance”-”input terminal.
6. Function Selector: It is used for power on
and changes the range of function.
7. Zero knob: Knob to zero when test low
capacitance.
4