1.7

The EMC requirements

The device complies with the requirements of EN61800-3:2004 (IEC61800-3) for second environment, category
C3, when a dedicated external EMC filter is applied.

1.7.1 EMC filter connection to inverter for trolley travelling.

DMCS007

c_kc310a

1. Supply
2. EMC filter KC-310-00
3. Inverter
4. Motor cable length max 3 m
5. 4 x 0,47

µ

F

Capacitors have to be placed as near the inverter as possible.

1.7.2 EMC filter connection to inverter for bridge travelling.

DMCS007

c_kc330a

1. Supply
2. EMC filter KC-330-00
3. Inverter
4. Motor cable length max 25 m
5. 4 x 1

µ

F

6. Input wires two times trough input ferrite rings

Capacitors have to be placed as near the inverter as possible.