Industrial power supplies, Connection details n l – Powersolve PDR Series User Manual

Page 2

Advertising
background image

Powersolve Electronics Ltd.  8A Arnhem Road,  Newbury, RG14 5RU.  England

Tel: 01635 521858  Fax: 01635 523771  Email: [email protected]

www.powersolve.co.uk

INDUSTRIAL POWER SUPPLIES

Ready Connection:

Options:

Add following suffix after part numbers for
option:

R = Redundant Function

Vadj

DC On

C1 COM C2 — +

Ready Signal

H

W

D

Mechanical Details:

Dimensions

(mm)

PDR72

PDR120 PDR200 PDR240 PDR500

D

110

110

110

110

110

H

100

100

100

100

109.5

W

60

90

90

120

210

N

Neutral Terminal no Polarity when DC Input

L

Line Terminal no Polarity when DC Input

Grounding Earth Terminal

COM

DC OK Output Signal, 10A Relay 1A Current Rating

C1

Normally Closed Connection

C2

Normally Open Connection

—

DC Negative Output Terminal

+

DC Positive Output Terminal

Vadj

Potentiometer for Output Voltage Adjust

DC ON

Green LED Indicator showing Output Present

Cs

Current Share Signal (PDR240 only)

Connection Details

N L

Case Material: Aluminium
Colour: Aluminium

Output Connector for PDR240 Series

Output Connector for PDR500 Series