Ac-dc converters – Powersolve MP Series User Manual
Page 3

Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: [email protected]
www.powersolve.co.uk
AC-DC Converters
ENVIRONMENTAL
Operating temperature
-20°C to 50°C (start @ 0°C)
(derate each output linearly to 50% at 70°C)
(-20°C to 40°C max. with rear air option)
Shock/Vibration
Mil-Hdbk 810E
Humidity
95% non-condensing
Storage temperature
-40°C to +85°C
Temperature coefficient
0.02% per °C
Cooling
Internal DC fan or customer provided air (option)
Safety Approvals
UL, CSA, IEC, VDE, BABT, CB, CE
Electrical Specification (ctd)
Note:
1. Single output modules only.
2. Single and main of dual output modules only.
3. Contact factory for optional preload if required.
Power Derating Curve
%
Rated
Total
Case
Load
Normal
Air Flow
30
20
40
60
80
100
35
40
45
50
55
60
65
70
TA – Ambient Temperature – °C
50
50