Ac-dc converter, Led status, Remote on/off – Powersolve PAK1500 Series User Manual
Page 3: Derating curve

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]
www.powersolve.co.uk
AC-DC Converter
LED Status
LED Colour
LED Signal
Status
Green LED
Solid
__________________________________
Power OK
Slow Blink
__ __ __
Power Standby
Red LED
Fast Blink
__ __ __ __ __ __ __ __ __ __
Over Voltage Protection (OVP)
Solid
__________________________________
Over Load Protection (OLP)
Output Short Circuit Protection (SCP)
Under Voltage Protection (UVP)
Slow Blink
__ __ __
Over Temperature Protection (OTP)
Intermittent Blink
__ __ __ __ __ __
Fan Failure
Interlace Blink
__ __ ______ __ __ ______ __ __
Power Failure
Remote ON/OFF
AUX
AUX
AUX
INH+
INH-
GND
INH+
INH-
GND
GND
SW
INH+
INH-
GND
SW
5V
5V
5V
2KΩ
2KΩ
2KΩ
5V
L: ON
H: OFF
Using internal 5V aux. source
ON/OFF control by NPN transistor
Using external source
Derating Curve