User guide – dbx ZC-BOB User Manual
Page 4

®
DriveRack
®
/ZonePRO
™
User Manual
4
ZC-Remote Control Wall Controllers
USER GUIDE
Diagram C
Diagram D
ZC-4
ZC-4 Binary App notes
SW4
SW3
SW2
SW1
Hex
Setting
0
0
0
0
0
0
0
0
0
1
1
1
0
0
1
0
2
2
0
0
1
1
3
3
0
1
0
0
4
4
0
1
0
1
5
5
0
1
1
0
6
6
0
1
1
1
7
7
1
0
0
0
8
8
1
0
0
1
9
9
1
0
1
0
A
10
1
0
1
1
B
11
1
1
0
0
C
12
1
1
0
1
D
13
1
1
1
0
E
14
1
1
1
1
F
15
Switches SW1-SW4 correspond to switch inputs 1-4 on the ZC4's
EuroBlock connector.Each switch connected to the ZC4 must be a
Dual Pole Single Throw (DPST). One pole of each switch should
be connected to the ground reference on the ZC4's EuroBlock con-
nector while the other pole should be connected to the +V refer-
ence. Because there are four switch inputs, there are 16 possible
switch combinations. In the chart above, a "0" cooresponds to a
switch connected to +V reference, while a "1" cooresponds to the
switch being connected to ground. None of the poles should be
left hanging but should either be connected to +V or ground.