8.5 Firmware Updates

Flash Update (1260, 1260m, 640, 640m)

A ZonePRO firmware release will include a PC application that will load the new firmware
version to a device connected via RS232. The receiving ZonePRO should be running. Follow
the directions in the PC flasher application.

If, for some reason, you are not able to update your firmware successfully using this method,
there is another “backdoor” method. This method forces the ZonePRO into a special Flash
Update Receive Mode:

Hold the <1> button while connecting power to the ZonePRO. A message similar to the
following will appear:

WAITING FOR”
FLASH DOWNLOAD”

2B100002

The device now accepts a flash download from the PC flasher application. Run the PC flasher
application then follow the instructions on the LCD when the flash completes.

Flash Update (1261, 1261m, 641, 641m)

A ZonePRO firmware release will include a PC application that will load the new firmware
version to a device connected via RS232. The receiving ZonePRO should be running. Follow
the directions in the PC flasher application.

If, for some reason, you are not able to update your firmware successfully using this method,
there is another “backdoor” method. This method forces the ZonePRO into a special Flash
Update Receive Mode:

In the “Help” tab of the program dialog of ZonePRO Designer select 641/1261 Operation
> Flash Start. Close ZonePRO Designer and open the PC flasher application. Follow the
directions in the PC flasher application. Disconnect and then reconnect the power to the
1261 when the flash is complete.

8.6 Factory Reset Procedures

In the event that a reset is required, the ZonePRO offers you the option of performing a
“Hard” or “Soft” Factory Reset.

The results of performing a “Soft” reset are:

• The state of the currently loaded scene’s parameters are reset to what has been stored

in flash for that scene (this invalidates the state of those parameters when the device
was last turned off).

• The currently loaded scene is reset to Scene 1.