Instruction Sheet

3B SCIENTIFIC® PHYSICS

U17250 Electroscope

6/03 ALF

®

The device is used for an introduction into the funda-
mentals of electrostatics and for displaying DC and AC
voltages as well as demonstrating the operating prin-
ciples of high voltage meters according to Braun.

1. Safety instructions

• Make sure that the insulator is always clean and

dry. If necessary use alcohol or spirits for cleaning.

• At high humidity and after transporting the unit

from a cool room into a warmer one, dry the elec-
troscope in a stream of hot air (e.g. a hair dryer).

2. Description, technical data

The electroscope consists of a metal baseplate on which
the iron shielding ring for defined field distribution is
mounted. The iron ring is equipped with a 4-mm socket
for earthing purposes. The support for needle with
pivot bearing is attached electrically insulated to the
shielding ring. The pointer is suspended asymmetri-
cally and so its weight delivers the restoring moment.
Inside the electrically conductive insulator at the up-
per part of the device there is a 4-mm socket for mount-
ing the sphere and capacitor plate.
For demonstration experiments the electroscope is suit-
able for shadow projection using a point source light.
Diameter:

130 mm

2.1 Scope of supply
1 Electroscope
1 Sphere with 4-mm plug
1 Capacitor plate with 4-mm plug
1 Capacitor plate on insulating rod

3. Operation

The electroscope is charged using friction rods stati-
cally charged by various friction-inducing materials
(e.g. U11053), or using a high-voltage power supply unit
(e.g. U21060).

3.1 Charging up the electroscope by touching it

with a statically charged body

•

Attach the sphere or capacitor plate to the elec-
troscope.

•

Rub the friction rod with the suitable material (PVC
or acrylic rods e.g. with plastic foil).

•

Touch the sphere or capacitor plate with the
charged rod. The pointer deflects.

•

Remove the friction rod, the pointer remains de-
flected.

•

Touch the sphere with your hand. The pointer re-
turns to normal.

•

When a high-voltage power supply is used then
attach the capacitor plate to the positive pole of
the power supply unit. Connect the negative pole

1

Sphere with 4-mm plug

2

Insulator

3

Shielding ring

4

Baseplate

5

Capacitor plate with 4-mm plug

6

Capacitor plate on insulating rod

7

4-mm socket

8

Support with pointer

1

2

3

4

5

6

7

8