3B Scientific High Current Coil User Manual

Page 2

Advertising
background image

4

2.1 Accessories
8497180 Transformer coil with yoke and clamps.
8614190 Transformer base.
8614192 Clamping mechanism for iron core.
8497420 Mains coil with 600-turn winding
8497331 Nails for Nail Fusion Experiment

3. Needle-point melting experiment

Caution: The melted part of the pin naturally falls down-
wards due to gravity.

•

Assemble the transformer as in Fig.1 and place it on a
heat-resistant surface.

•

Place pins into the openings provided and secure
them with the knurled screws.

•

Mount the mains coil and switch it on.

•

The pin starts to glow because of the high current
and gravity causes it to bend downwards.

•

After the experiment, allow the remains of the pins
to cool down for at least 5 minutes.

Fig.1

ELWE Didactic GmbH • Steinfelsstr. 5 • 08248 Klingenthal • Germany • www.elwedidactic.com

3B Scientific GmbH • Rudorffweg 8 • 21031 Hamburg • Germany • www.3bscientific.com

Technical amendments are possible