3B Scientific Coil D, 900 Turns User Manual

Page 2

Advertising
background image

Elwe Didactic GmbH ▪ Steinfelsstr. 5 ▪ 08248 Klingenthal ▪ Germany ▪ www.elwedidactic.com

3B Scientific GmbH ▪ Rudorffweg 8 ▪ 21031 Hamburg ▪ Germany ▪ www.3bscientific.com

Rights to amend technical specification reserved

© Copyright 2012 3B Scientific GmbH

Coils 1000988, 1012859, 1000989,

1000990 can be subject to high or low

voltages when used as secondary

coils. They are not suitable for

experiments performed by students.

Eingriffe in den Aufbau eines Transforma-

tors nur bei abgeschalteter Primärspannung

vornehmen.

Always use safety cables for experiments.

Do not exceed the maximum voltage over

any length of time.

Do not open the coils’ cases.

Do not allow the equipment to come into

contact with liquids.

If the coils should become overloaded, they

must be allowed to cool before switching on

the current again.

Do not cover the air vents.

The resulting magnetic fields can cause damage

to or even destroy electrical/electronic compo-

nents and equipment or electromagnetic storage

media. Such items must be kept away from the

coil by at least the amount specified for safety.


2. Description

Coils, safe to touch, for use as primary or sec-

ondary coils in combination with the transformer

core D (1000976).
Coils with a variety of winding turns and interme-

diate taps. A suitable choice of coil enables all

experiments to be performed safely at low volt-

age. Simple whole-number winding and interme-

diate tap ratios allow the transformer laws to be

derived in clear and understandable fashion.
Coils are made of impact-resistant plastic. The

ends and taps for the coils are equipped with

safety sockets. Number of turns, maximum cur-

rent for long-term operation, effective resistance,

direction of windings and inductance are speci-

fied on the case of the coil. The current may

reach approximately double the long-term ma-

ximum for short periods (10 seconds).

The coil with 900 windings has a reversible tem-

perature cut-out inside, which trips when the

winding temperature reaches 85°C. It resets

after about 10-20 minutes depending on the

ambient temperature.


3. Accessories

Mains coil D with connecting lead (230 V, 50/60 Hz)

1000987

or

Mains coil D with connecting lead (115 V, 50/60 Hz)

1000986
Transformer core D

1000976


4. Care and maintenance

Before cleaning the coil, disconnect it from

its power supply.

Use a soft, damp cloth to clean it.


5. Disposal

The packaging should be disposed of at

local recycling points.

Should you need to dispose of the coil itself,

never throw it away in normal domestic

waste. Local regulations for the disposal of

electrical equipment will apply.


6. Technical data

Connections::

4-mm safety sockets

Dimensions:

120 x 90 x 70 mm

3

Opening for iron core:

42 x 42 mm

2

Winding turns Tap(s)

Resistance

Max. current

Inductance

1000985

72

6/30/54/66/72

0,1 Ohm

12 A

0.23 mH

1000988

600

200/600

3 Ohm

2.2 A

15 mH

1012859

900

4.8 Ohm

5 A (7 min)

34 mH

1000989

1200

400/1200

12 Ohm

1.2 A

60 mH

1000990

6000

2000/6000

300 Ohm

0.2 A

1.5 H