age. In the event of any malfunc-
tion/operational defect or visible damage,
switch off the unit immediately and secure it
from unintentional use.
•
The instrument may only be connected to
the mains via a socket that has an earth
connection.
•
Before making any connections, check the
experiment leads for damaged insulation
and exposed wires.
•
Never cover the air vents and heat sink at
the rear of the housing. These are neces-
sary in order to ensure sufficient circulation
of air required for cooling the components
inside the equipment.
•
The equipment may only be
opened/repaired by qualified and trained
personnel.
2. Description
The transformer with rectifier provides AC and
DC voltages that can be varied from 2 V to 14 V
in steps of 2 V. The outputs are insulated from
the mains supply line. The built-in bridge rectifier
with downstream charging capacitor provides
smoothed DC voltages. The voltage outputs are
protected by a thermal safety cutout.
The transformer 1003557 is for operation with a
mains voltage of 115 V (±10%), and the unit
1003558 is for operation with a mains voltage of
230 V (±10%).
3. Technical data
Mains supply voltage: see rear panel
Output voltages:
2 V AC/DC
4 V AC/DC
6 V AC/DC
8 V AC/DC
10 V AC/DC
12 V AC/DC
14 V AC/DC
Output current:
max. 5 A
Connections:
4 mm safety sockets
Dimensions:
260x 140x 130 mm
3
approx.
Mass:
3.1 kg approx
4. Operation
Caution:
The AC and DC outputs cannot be used at the
same time.
4.1 Obtaining an AC voltage
•
Connect the unit to the mains supply.
•
Connect the load to the AC output sockets.
•
Set the voltage control to give the required
voltage; if necessary connect a voltmeter in
parallel with the load.
•
Push the mains switch to the up position; the
mains indicator light shows green.
4.2 Obtaining a DC voltage
•
Connect the unit to the mains supply.
•
Connect the load to the DC output sockets.
•
Set the voltage control to give the required
voltage; if necessary connect a voltmeter in
parallel with the load.
•
Push the mains switch to the up position; the
mains indicator light shows green.
5. Safety instructions
Overcurrent cutout switch:
If the overcurrent cutout switch has tripped:
•
Disconnect the mains plug.
•
Determine the cause of the overcurrent and
eliminate it.
•
Re-connect the unit to the mains supply.
•
Press the overcurrent cutout switch.
6. Care and maintenance
•
Before cleaning the equipment, disconnect it
from its power supply.
•
Use a soft, damp cloth to clean it.
7. Disposal
•
The packaging should be disposed of at
local recycling points.
•
Should you need to dispose of the equip-
ment itself, never throw it away in normal
domestic waste. Local regulations for the
disposal of electrical equipment will apply.