age. In the event of any malfunc-
tion/operational defect or visible damage,
switch off the unit immediately and secure it
from unintentional use.

The instrument may only be connected to
the mains via a socket that has an earth
connection.

Before making any connections, check the
experiment leads for damaged insulation
and exposed wires.

Never cover the air vents and heat sink at
the rear of the housing. These are neces-
sary in order to ensure sufficient circulation
of air required for cooling the components
inside the equipment.

The equipment may only be
opened/repaired by qualified and trained
personnel.

2. Description

The transformer with rectifier provides AC and
DC voltages that can be varied from 2 V to 14 V
in steps of 2 V. The outputs are insulated from
the mains supply line. The built-in bridge rectifier
with downstream charging capacitor provides
smoothed DC voltages. The voltage outputs are
protected by a thermal safety cutout.
The transformer 1003557 is for operation with a
mains voltage of 115 V (±10%), and the unit
1003558 is for operation with a mains voltage of
230 V (±10%).

3. Technical data

Mains supply voltage: see rear panel
Output voltages:

2 V AC/DC

4 V AC/DC

6 V AC/DC

8 V AC/DC

10 V AC/DC

12 V AC/DC

14 V AC/DC

Output current:

max. 5 A

Connections:

4 mm safety sockets

Dimensions:

260x 140x 130 mm

3

approx.

Mass:

3.1 kg approx

4. Operation

Caution:
The AC and DC outputs cannot be used at the
same time.

4.1 Obtaining an AC voltage

Connect the unit to the mains supply.

Connect the load to the AC output sockets.

Set the voltage control to give the required
voltage; if necessary connect a voltmeter in
parallel with the load.

Push the mains switch to the up position; the
mains indicator light shows green.

4.2 Obtaining a DC voltage

Connect the unit to the mains supply.

Connect the load to the DC output sockets.

Set the voltage control to give the required
voltage; if necessary connect a voltmeter in
parallel with the load.

Push the mains switch to the up position; the
mains indicator light shows green.

5. Safety instructions

Overcurrent cutout switch:
If the overcurrent cutout switch has tripped:

Disconnect the mains plug.

Determine the cause of the overcurrent and
eliminate it.

Re-connect the unit to the mains supply.

Press the overcurrent cutout switch.

6. Care and maintenance

Before cleaning the equipment, disconnect it
from its power supply.

Use a soft, damp cloth to clean it.

7. Disposal

The packaging should be disposed of at
local recycling points.

Should you need to dispose of the equip-
ment itself, never throw it away in normal
domestic waste. Local regulations for the
disposal of electrical equipment will apply.