6 troubleshooting – Crown Audio Macro-Tech MA5002VZ User Manual

Page 17

Advertising
background image

page 17

MA-5002VZ Power Amplifier

Operation Manual

CONDITION: Normal operation.

POSSIBLE REASON:

• This is normal operation for your amp.

CONDITION: Distorted sound.

POSSIBLE REASON:

•

Input signal level is too high. Turn down

your amplifier level controls. NOTE: Your
amplifier should never be operated at a
level which causes the Signal/IOC LEDs
to constantly indicate an IOC condition.

6 Troubleshooting

• The amp is set for Parallel Mono mode.

CONDITION: No power to the amplifier.

POSSIBLE REASON:

•

The amplifier's Power switch is off.

•

The amplifier is not plugged into the power

receptacle.

•

The amplifier's low-voltage power supply fuse

has blown. Return amp to Crown or an
authorized Crown Service Center for
servicing.

CONDITION: No sound.

POSSIBLE REASON:

•

The amplifier has just been turned on and is

still in the 4-second turn-on delay.

•

The amplifier is being held in Standby Mode

by an installed IQ PIP module.

•

The amplifier is in drive protection mode.

This can occur with improper source sig-
nals like infrasonic square waves or input
overloads that excessively clip the input
signal.

•

No input signal

•

Input signal level is very low.

•

Level controls are turned down.

Key

•

Output current is being limited because the

load impedance of the channel is too low,
or the output is shorted.

•

ODEP limiting has been activated. Take

appropriate measures to keep the ampifier
out of ODEP limiting (see Section 5.1.1 for
more information about ODEP).

Advertising