Data sheet, Sv01, Technical data – Procom SV01 User Manual
Page 3

Data Sheet
SV01
Power Supply Module
The Symbols on the Front Plate and their Meaning:
The System Blinker
Addressing from processor taking place (refer to the CPU1 data
sheet for more information)
I/O Input/Output
BUS output works as push-push operation with the system blinker
BUS input works as push-pull operation with the system blinker
+5 V Output Voltage
+5 V supply voltage available for the modules
-5 V Output Voltage
-5 V supply voltage available for the modules
Al
Malfunction Signal (Alarm)
Group malfunction signals
U
Input Voltage
48 V available
Technical Data:
Input Voltage:
From 36 V to 75 V, nominal 48 V DC
Output Voltage:
+/-5 V
Idle Current at 48 V:
56 mA
Load Current:
Max. 1 A
Temperature Range:
0 °C to 45 °C
Date:
25.03.2009 Page:
3/4 Author:
HS
Document-No.:
DB_SV01_2100_01