Data sheet, 4lsl – Procom 4LSL User Manual
Page 6
 
Data Sheet
4LSL
 
 
Loudspeaker Function Card
Commissioning Functions
The 4LSL measuring module includes additional commissioning and servicing 
aids to better control the measurement equipment or the loudspeaker circuits. 
 
These are: 
 
- Switchable drive display (VU meter) to check precisely all signals to be meas-
ured
- Display of the most important functions on the front plate 
- Automatic or manual calibration of loudspeaker circuits 
- Diverse group and individual messages 
- PC-based configuration 
- Measurement data transmission to the DVS-21 central system 
- Simulation of all processes which the module has 
 
Summary of the Functions
- Precision measuring for impedance error detection: 1-100% in 1% steps
(% of installed loudspeaker load)
- Number
of
independent
loudspeaker circuits or measurement channels:
4
- Measurement channels can be individually switched on/off 
- Loudspeaker 
minimum/maximum
load
per channel: 2.5 Watt / 150 Watt
- Loudspeaker load check during commissioning 
- Manually or automatically configurable impedance deviation limits 
- Verification of impedance deviation through automatic multiple subsequent 
measurements
- Automatic or manual measuring procedure 
- Checking of the test signal generator before each measurement 
- Wire breakage or short circuit detection 
- Allocation of an occurring earth leakage to a loudspeaker circuit (earth leak-
age detection through TG01)
- Transfer of all measurement data to the DVS-21 central system 
- Display of all statuses by LEDs on the front plate 
- Loudspeaker circuit relays: 4 (1/channel) 
- Generation of positive and negative public address acknowledgements 
- Programmable night-reduction function for public address acknowledgement 
- Configurable amplifier protection function for loudspeaker circuit short circuit 
- Making possible public address in the case of a short circuit (group public 
address)
- Diverse group and individual messages 
- Full control over all procedures through the DVS-21 central system 
- PC-based 
configuration
- Commissioning and service aids on-board
Further details can be found in the commissioning instructions.
 
 
Date:
13.03.2009 Page:
6/7 Author:
HS
Document-No.:
DB_4LSL_2830_01
© 2008 ProCom, All rights and technical changes reserved