Littelfuse LD Series User Manual

Powr-bloks, Powr-gard, Blocks and holders datasheet

Advertising
background image

Littelfuse.com

© 2013 Littelfuse POWR-GARD

®

Products

POWR-GARD

®

Blocks and Holders Datasheet

Rev: 062613

1 of 6

Specifications

Voltage Rating

600 V

Current Rating

Based on NEC Table 310.16, using 75°C copper wire

Material

Phenolic rated at 150°C and Thermoplastic

rated at 125°C (LD1400 and LS1300 series only)

Connector

Standard: Highly con duc tive aluminum, tin plated

Copper: Highly conductive copper, tin plated

Flammability Rating UL94 V-0

Approvals

UL Recognized - LD/LS Series (File: E171395)

LFD/LFS Series (File: E309688)

CSA Certified - LD/LS Series (File: LR700111)

LFD/LFS Series (File: 007316_0_000)

Environmental

RoHS compliant, Lead (Pb) free

Ordering Information

See Selection Guide on next page

Web Resources

For dimension, CAD and 3-D drawings, visit:
Littelfuse.com/powrbloks

powr-bloks

Distribution Blocks • Splicer Blocks • Covers

Description

POWR-BLOKS

TM

power distribution blocks offer a safe,

convenient way of splicing cables, providing a fixed junction
tap-off point or splitting primary power into secondary
circuits. Lx2xxx-DIN series offers integral DIN-Rail mount
and an optional hinged safety cover.
Optional power distribution block covers provide protection
against accidental shorting between poles caused by
loose wires, tools, or other conductive material. They also
protect personnel from accidentally contacting energized
connectors. To order protective covers, match the number
of poles for the block to the cover.

Applications

Typical applications include heating, air conditioning and
refrigeration systems, el e va tor systems, material handling
equipment, control panels, motor controls, switchgear,
and anywhere power needs to be distributed to more
than one load.

Connectors

Box lug connectors are designed for use with a single, solid
or class B or C stranded conductor. Use of more than one
con ductor per connector opening or use of extra-flexible,
fine-stranded conductors, such as welding cable, voids the
UL Listing and may cause overheating. Manufacturers of
cable ter minations can furnish crimp-on sleeves for fine
stranded conductors which permit these conductors to be
used with box lugs.

Ampere Ratings

The ampere rating per pole for power distribution blocks is
based on the line ampacity of 75°C insulated conductors per
NEC

®

Table 310.16. If 60°C insulated conductors are used,

load must not exceed the ampacity of 60°C conductors.
Use of conductors rated in excess of 75°C is permitted (for
example 90°C), however, load must not exceed the ampacity
of 75°C conductors.

Hinged Plastic Covers

Catalog/

ordering

number

For use with

distribution/spliCer bloCk no.

poles

0LCH1321Z

LD2xxx-1DIN / LS2xxx-1DIN

1

0LCH1322Z

LD2xxx-2DIN / LS2xxx-2DIN

2

0LCH1323Z

LD2xxx-3DIN / LS2xxx-3DIN

3

Note: Optional hinged covers snap on to blocks.

Clear Plastic Covers

Catalog/

ordering

number

For use with

distribution/spliCer bloCk no.

poles

LPBC02

LD0xxx-2 / LS0xxx-2

2

LPBC03

LD0xxx-3 / LS0xxx-3

3

LPBC21

LD2xxx-1 / LS2xxx-1

1

LPBC22

LD2xxx-2 / LS2xxx-2

2

LPBC23

LD2xxx-3 / LS2xxx-3

3

LPBC31

LD3xxx-1 / LS3xxx-1

1

LPBC32

LD3xxx-2 / LS3xxx-2

2

LPBC33

LD3xxx-3 / LS3xxx-3

3

LPBC41

LD4xxx-1 / LS4xxx-1

1

LPBC42

LD4xxx-2 / LS4xxx-2

2

LPBC43

LD4xxx-3 / LS4xxx-3

3

LPBC51

LD5xxx-1 / LS5xxx-1

1

LPBC52

LD5xxx-2 / LS5xxx-2

2

LPBC53

LD5xxx-3 / LS5xxx-3

3

Note: For installation of optional clear plastic covers, use the screws provided with each

cover.