Littelfuse M0600 Series User Manual

M0600 series, Engine control, Advanced description

Advertising
background image

Engine Control

© 2013 Littelfuse Protection Relays & Controls

Advanced

Description

The M0600 Shutdown Unit is a back-up protection device

designed for marine engines. It is ensuring safety shutdown

of the engine in case normal primary shutdown fails. The

unit works as a stand-alone protection unit, and is for DIN-rail

mounting. Alternatively it can be mounted directly on the

back of the M2000 Engine Controller.
Together with Engine controller units M2000 it can be

used to build a complete control, alarm and safety system

for marine engines. The unit has inputs for overspeed, low

oil pressure and one more user defined parameter, which

could be e.g. high water temperature. It also has an input to

indicate that the engine is running and one to indicate that

the engine is stopping.
The monitoring of low oil pressure is only active when the

engine is running with a few seconds delay after detection

of the running signal. This time delay can be defined via

programming switches. A normally open (NO) output relay

can give a closing signal which can be used to stop the

engine via it’s stop coil, and a normally closed (NC) relay can

open in order to stop the engine via the fuel valve. The length

of the relay activation time can be defined via programming

switches.
The M0600 is type approved by major marine classification

societies.
Input terminals
1. OVS

Overspeed

2. SPA

Spare

3. LOP

Low Oil Pressure

4. RUN

Running (Crank Disconnect)

5. STP

Stop (Engine Stop)

6. + 24 V Supply Voltage (+)
7. –

Supply Voltage (-)

8. –

Supply Voltage (-)

Ordering Information

Simplified Circuit Diagram

Features & Benefits

www.littelfuse.com/m2600

M0600 SerieS

Shutdown Unit

Ordering nuMber

delAy fOr SpA

delAy fOr lOp

M0600.0010

100 msec.

500 msec.

M0600.0020

1.5 sec.

1.5 sec.

feAtureS

benefitS

Stand-alone unit

Runs independantly, as a back-up for the M2000

Combines with M2000

Provides complete redundancy

Mountable on

rear of M2000

Flexibility of use; Also DIN-rail mountable

SHUTDOWN

+ –

24 V

+24 V

STP

RUN

LOP

SPA

OVS

SENSOR

INPUTS

NO

COM

NC

M0600

(Shut-Down Unit)

Rev: 4-A-050313