118

Revised: June 4, 2010

POLYFUSE

®

Resettable PTCs

© 2010 Littelfuse, Inc.

LT Series

Specifications are subject to change without notice.

Please refer to www.littelfuse.com/series/LT.html for current information.

Axial Lead Battery Strap Type > LT Series

Ambient Operation Temperature

-40°C

-20°C

0°C

20°C

40°C

50°C

60°C

70°C

85°C

Part Number

Hold Current (A)

15LT070

1.20

1.09

0.85

0.70

0.50

0.45

0.35

0.28

0.16

15LT070S

1.20

1.09

0.85

0.70

0.50

0.45

0.35

0.28

0.16

24LT100

1.86

1.60

1.40

1.00

0.80

0.70

0.60

0.44

0.23

24LT100S

1.86

1.60

1.40

1.00

0.83

0.70

0.60

0.44

0.23

24LT100SS

1.86

1.60

1.40

1.00

0.83

0.70

0.60

0.44

0.23

24LT180

3.13

2.68

2.20

1.80

1.33

1.10

0.90

0.65

0.36

24LT180S

3.13

2.68

2.20

1.80

1.33

1.10

0.90

0.65

0.36

24LT180SS

3.13

2.68

2.20

1.80

1.33

1.10

0.90

0.65

0.36

24LT190

3.32

2.86

2.40

1.90

1.48

1.25

1.10

0.79

0.43

24LT260

4.30

3.72

3.10

2.60

1.98

1.69

1.40

1.11

0.60

24LT300

5.10

4.40

3.70

3.00

2.30

1.95

1.60

1.25

0.69

24LT310

5.36

4.58

3.70

3.10

2.36

2.01

1.70

1.30

0.71

24LT340

5.52

4.79

4.00

3.40

2.60

2.24

1.90

1.51

0.78

Temperature Rerating

Temperature Rerating Curve

-40

-30 -20

-10

0

10

20

30

40

50

60

70

80

10%

30%

50%

70%

90%

110%

130%

150%

170%

Temperature (°C)

Percentage of Rated Current

190%

Average Time Current Curves

The average time current curves and Temperature Rerating curve performance is affected
by a number or variables, and these curves provided as guidance only. Customer must
verify the performance in their application.

0.01

0.1

1

10

1

10

100

1000

0.70 A

1.00 A 1.80 A 1.90 A 2.60 A 3.00 A 3.10 A 3.40 A

LT

Time in Seconds

Current in Amperes

Advertising