current Transformers

currenT TranSfOrmerS

currenT TranSfOrmerS

Product

features

inner diameter

accessory for

CT200 (PGC-2056)

Current Transformer

Detects phase current or ground-fault

current. (200-A primary)

56 mm

(2.20")

SE-330 SE-105/107 FPS

SE-701 MPU-32 FPU-32

MPS SE-325 AF1000

CT200L (PGC-2089)

Current Transformer

Detects phase current or ground-fault

current. (200-A primary)

89 mm

(3.50")

SE-701 SE-105 MPU-32

SE-107 MPS FPU-32

AF1000 FPS

EFCT-26 (PGC-3026)

Ground-Fault Current

Transformer

Sensitive current transformer used to

detect ground-fault current. (5-A primary)

26 mm

(1.02")

SE-330 MPS MPU-32

SE-701 FPU-32 FPS

EL731

EFCT-1 (PGC-3082)

Ground-Fault Current

Transformer

Sensitive current transformer used to

detect ground-fault current. (5-A primary)

82 mm

(3.23")

SE-330 MPS MPU-32

SE-701 FPU-32 FPS

EL731

EFCT-2 (PGC-3140)

Ground-Fault Current

Transformer

Sensitive current transformer used to

detect ground-fault current. (5-A primary)

140 mm

(5.50")

SE-701

MPU-32

EL731

MPS

FPU-32

FPS

EFCT-1FC (PGC-31FC)

Flux Conditioner

Fits in the EFCT-1 window to reduce

saturation and prevent false operation

due to large surge currents.

70 mm

(2.75")

EFCT-1

SE-CS10-2.5 (PGC-4064)

Current Sensor

Detects ground-fault current.

64 mm

(2.50")

SE-134C SE-135 SE-145

SE-CS10-4 (PGC-4108)

Current Sensor

Detects ground-fault current.

108 mm

(4.25")

SE-134C SE-135 SE-145

SE-CS10-6 (PGC-4160)

Current Sensor

Detects ground-fault current.

160 mm

(6.31")

SE-134C SE-135 SE-145

SE-CS10-8 (PGC-4210)

Current Sensor

Detects ground-fault current.

210 mm

(8.25")

SE-134C SE-135 SE-145

SE-CS30-26 (PGC-5025)

Ground-Fault Current Transformer

Current Transformer for low-level

ground faults, flux conditioner

is standard. (30-A primary)

25 mm

(0.98")

SE-704

SE-330

SE-701

PGR-6100

MPU-32

MPS

FPU-32

FPS

SE-CS30-70 (PGC-5060)

Ground-Fault Current Transformer

Current Transformer for low-level

ground faults, flux conditioner

is standard. (30-A primary)

60 mm

(2.36")

SE-704

SE-330

SE-701

PGR-6100

MPU-32

MPS

FPU-32

FPS

SE-CS30-4 (PGC-5095)

Ground-Fault Current Transformer

Current Transformer for low-level

ground faults, flux conditioner

is standard. (30-A primary)

95 mm

(3.74")

SE-704

SE-701

PGR-6100

MPU-32

MPS

FPU-32

FPS

SE-CS30-5 (PGC-5130)

Ground-Fault Current Transformer

Current Transformer for low-level

ground faults, flux conditioner

is standard. (30-A primary)

130 mm

(5.12")

SE-704

SE-701

PGR-6100

MPU-32

MPS

FPU-32

FPS

SE-CS30-8 (PGC-5200)

Ground-Fault Current Transformer

Current Transformer for low-level

ground faults, flux conditioner

is standard. (30-A primary)

200 mm

(7.87")

SE-704

SE-701

PGR-6100

MPU-32

MPS

FPU-32

FPS

SE-CS40-6

Current Sensor

Detects ground-fault current

160 mm

(6.31”)

SE-135

SE-145

Advertising