Sidactor, Protection thyristors, Teccor – Littelfuse SDP Series SOT23-5 User Manual

Page 2: Brand sidactor, Dsl protection devices, The epoxy meets ul 94v-0 ratings

Advertising
background image

SIDACtor

®

Protection Thyristors

2

Revised: August 6, 2013

© 2013 Littelfuse, Inc.

Specifications are subject to change without notice.

Please refer to www.littelfuse.com for current information.

Teccor

®

brand SIDACtor

®

DSL Protection Devices

Parameter Name

Symbol

Test Conditions

Value

Units

Lightning surge waveforms

I

pp

8x20µs

50

A

min

max

Operating Free Temperature Range

T

A

-40

+85

°C

Junction temperature

T

J

-40

+150

°C

Storage temperature

T

STG

-40

+150

°C

Maximum Ratings

Notes:
- The device also complies with IEC 61000-4-2 ESD ±15kV (air discharge), ±8 kV(contact discharge) and IEC 61000-4-4 EFT 40A(5/50nS) in equipment level ESD test when used behind the

xDSL transformer.

- The device must initially be in thermal equilibrium with -40°C < T

J

< +150°C

Mechanical dimensions, recommended layout dimensions

E

B

D

A

A2

A1

C

F

G

0.138(3.5)

0.047(1.2)

0.037(0.95)

0.024(0.60)

0.037(0.95)

Dimension are in inches

(and millimeters).

Dimension

Inches

Millimeters

Min

Max

Min

Max

A

0.035

0.057

0.90

1.45

A1

0

0.004

0

0.10

A2

0.035

0.051

0.90

1.30

B

0.014

0.020

0.35

0.50

C

0.004

0.008

0.09

0.20

D

0.11

0.118

2.80

3.00

E

0.059

0.069

1.50

1.75

F

0.102

0.118

2.6

3.00

G

0.004

0.024

0.10

0.60

The epoxy meets UL 94V-0 ratings

.

- The lightning surge may be repeated after the device returns to its initial conditions.

Advertising