Polyfuse, Resettable ptcs, Axial lead battery strap type > lr series – Littelfuse LR Series User Manual

Page 2

Advertising
background image

114

Revised: June 4, 2010

POLYFUSE

®

Resettable PTCs

© 2010 Littelfuse, Inc.

LR Series

Axial Lead Battery Strap Type > LR Series

Specifications are subject to change without notice.

Please refer to www.littelfuse.com/series/LR.html for current information.

Ambient Operation Temperature

-40°C

-20°C

0°C

23°C

40°C

50°C

60°C

70°C

85°C

Part Number

Hold Current (A)

15LR190

2.80

2.50

2.30

1.90

1.60

1.50

1.40

1.20

1.00

15LR190S

2.80

2.50

2.30

1.90

1.60

1.50

1.40

1.20

1.00

15LR260

3.80

3.40

3.10

2.60

2.20

2.00

1.90

1.70

1.40

15LR260S

3.80

3.40

3.10

2.60

2.20

2.00

1.90

1.70

1.40

15LR380

5.50

4.90

4.40

3.80

3.30

3.00

2.80

2.50

2.10

20LR450

6.50

5.80

5.30

4.50

3.90

3.60

3.30

2.90

2.50

20LR550

8.00

7.10

6.20

5.50

4.70

4.30

4.00

3.60

3.00

20LR600

8.70

7.80

7.10

6.00

5.20

4.70

4.40

3.90

3.30

20LR730

10.60

9.50

8.60

7.30

6.30

5.70

5.40

4.70

4.00

Temperature Rerating

Temperature Rerating Curve

B

A

A

B

-40 -30 -20

-10

0

10

20

30

40

50

60

70

80

10%

30%

50%

70%

90%

110%

130%

150%

170%

Temperature (°C)

Percentage of Rated Current

15LR190
15LR190

S

15LR260

A

B

Line/Part Number:

15LR380
15LR550
15LR600
20LR730

• 15LR260
• 15LR260

S

• 15LR450

Average Time Current Curves

The average time current curves and Temperature Rerating curve performance is affected
by a number or variables, and these curves provided as guidance only. Customer must
verify the performance in their application.

0.01

0.1

1

10

1

10

100

1000

1.90 A

2.60 A

3.80 A

4.50 A

5.50 A

6.00 A

7.30 A

Time in Seconds

Current in Amperes

LR

Advertising