SENA ProBee-ZE20S-SEME User Manual
Page 94
ProBee-ZE20S-SExx User Guide Rev 1.8
94
CA PUBLIC KEY & DEVICE PRIVATE KEY: <value><CR>
OK<CR>
7.12.19 AT+SETCBKEKEY
Description
Lock CBKE Data Token. Once the CBKE Data Token is locked, it cannot be
changed and erased.
Execute
AT+SETCBKEKEY<CR>
Response
CBKE DATA TOKEN IS LOCKED<CR>
DEVICE IMPLICIT CERT: <value>
CA PUBLIC KEY & DEVICE PRIVATE KEY: <value><CR>
OK<CR>
7.13 ProBeeSESI (Energy Service Interface) Profile Commands
7.13.1 AT+PRSETPUBLISH or AT+PSP
Description
Send ‘Publish Price’ command(Price cluster) to destination node. (server-side
command)
Execute
AT+DEST=<address>,<endpoint><CR>
AT+PRSETPUBLISH=<providerID>,<issuerID>,<unit
of
measure>,<currency>,<price
tier>,<number
of
price
tiers>,<duration
in
minites>,<price>,<price ratio><CR>
Response
OK<CR> or ERROR<CR>
7.13.2 AT+PRLABEL or AT+PLB
Description
Get/Set Price Label. This value will be used in AT+PRSETPUBLISH.
Execute
AT+PRLABEL?<CR>
AT+PRLABEL=<value><CR>
Response
<value>
OK<CR>
OK<CR> or ERROR<CR>
7.13.3 AT+PRCURRENTTIME or AT+PCT
Description
Get/Set Price Current Time. This value will be used in AT+PRSETPUBLISH. The
format of time is determined by ATU value.
Execute
AT+PRCURRENTTIME?<CR>
AT+PRCURRENTTIME=<UTC time>
Response
<UTC time><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
01-01-2000/00:00:00
Range
01-01-2000/00:00:00 - 02-07-2136/06:28:15
7.13.4 AT+PRSTARTTIME or AT+PST
Description
Get/Set Price Start Time. This value will be used in AT+PRSETPUBLISH. The