Promi-SD User Manual – Appendix A. AT Commands

A-4

Copyright © 2006 Sena Technologies, Inc. All rights reserved.

Command Description

1

ATZ

SD Response

OK

Purpose

Software Reset

Description

This is the same effect as power off and on.
This command disconnects Bluetooth device, and stops ongoing task. After rebooting,
the status is decided by the preset operation mode.
Some AT commands need ATZ to take effect.

Reference

AT&F, AT+BTCSD, AT+UARTCONFIG

2

AT&F

SD Response

OK

Purpose

Hardware reset

Description

This is the same effect as initialization by reset button.
All parameters are initialized to factory defaults. The storage of Promi-SD is cleared
completely.

Reference

ATZ

3

AT

SD Response

OK

Purpose

Check the connection status with host equipment

Description

Check if the connection to host equipment is normal. The serial parameters of Promi-SD
must be same as those of host equipment. If not, SD response is none or ‘ERROR’ or
abnormal sequence of strings.

Reference

AT+UARTCONFIG, ATZ, AT&F

4

AT+UARTCONFIG,Baudrate,Parity,Stopbit,Hwfc (SD101/202)

AT+UARTCONFIG,Baudrate,Parity,Stopbit (SD205)

SD Response

OK

Purpose

Set Serial parameters

Parameters

Baudrate=1200/2400/9600/14400/19200/38400/57600/115200/230400 (Default=9600)
Parity=N/E/O (Default=N)
Stopbit=1/2 (Default=1)
Hwfc(Hardware Flow Control)=0/1 (Default=1) (Only SD101/202)
* SD205 use dipswitch.

Description

The Serial parameters can be set or changed. The factory default is 9600, N, 1.
To take effect of this command, ATZ or power off and on.

Reference

AT, ATZ, AT&F, ATS