AP-DWS1000 Drinking Water Appliance Owner’s Manual

Installation Precautions

6888931 0701

Installation and
Operating Instructions

•

Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system.

•

Installation must comply with state and local
plumbing codes.

•

Systems certified for cyst reduction may be
used on disinfected water that may contain
filterable cysts.

•

System must be protected from freezing. Drain
filter when room temperature drops below
40°F (4.4°C).

•

Do not install on line pressure above 125 psi
(862 kPa).

•

Do not install on hot water line. Maximum
temperature allowed is 100°F (38°C).

•

The filter must be installed with the inlet and
outlet ports as labeled. Make sure not to
reverse connections.

•

Do not use wicking or sealer for fitting connections
into head of filter. Use Teflon

®

tape for connections.

•

Do not use torch or other high temperature
sources near filter or plastic cartridge.

•

Do not install near electric wires or water pipes
which will be in the path of drill when selecting
the position to mount bracket.

•

Do not install in direct sunlight.

•

Allow a minimum of 2” (5cm) clear space
under filter to facilitate cartridge change.

•

Mount filter in such a position as to prevent it
from being struck by other items.

Teflon is a registered trademark of E.I. DuPont.