External midi control, Operating levels – Universal Audio UAD SYSTEM ver.6.3.2 User Manual

Page 81

Advertising
background image

UAD System Manual

- 81 -

Chapter 7: Using UAD Powered Plug-Ins

External MIDI Control

UAD Powered Plug-In parameters can be controlled by an external MIDI con-
troller, if this feature is supported by the host application. Each host applica-
tion has its own particular methods for external MIDI control. Consult the host
application documentation for specific instructions on using external MIDI
control with the application.

Operating Levels

Except as noted in

Table 4

below, the internal operating level of most UAD

Powered Plug-Ins is typically –18 dBFS. 0 dBFS is calibrated to +4 dBu with
18 dB of headroom, so 0 dBFS is the equivalent of +22 dBu in the analog do-
main.

Table 4. UAD Powered Plug-In Internal Operating Levels

UAD Powered Plug-In

Typical Internal Operating Level

0 dBFS Equivalent

Most

–18 dBFS

+22 dBu

Ampex ATR-102

–12 dBFS

+16 dBu

Manley Massive Passive

–14 dBFS

+18 dBu

Neve 33609 (selectable)

–14 dBFS
–18 dBFS
–22 dBFS

+18 +dBu
+22 +dBu
+26 +dBu

Studer A800

–12 dBFS

+16 dBu

Advertising