Maintenance Information


Meter Calibration

The 2-1176 meters may occasionally need to be calibrated. This is accomplished by adjusting the
Zero Set potentiometer, located through a small hole on the front panel between each channel’s Input
and Output knobs.

The procedure for adjusting the meter is as follows:

1.

Power on the 2-1176.

2.

Set the Meter switch for the channel being calibrated to its +4 position.

3.

Set the Input control for the channel being calibrated fully off (turn the knob fully

counterclockwise).

4.

Use a small screwdriver to slowly adjust that channel’s Zero Set potentiometer so that its

meter reads 0 dB. Watch how the meter settles before completing the calibration.


Changing Voltage

The 2-1176 can operate from 100 V to 240 VAC / 50-60 Hz. The internal power supply is self-sensing
and will automatically work throughout this voltage range.