Relay

DESCRIPTION

The PRO-2RE-1PM-12V-...-TNC is used in simplex systems to avoid a

simultaneous transmission on two channels.
When transmitting on one channel, the other channels change to LOAD

to make sure that the system is secured against a simultaneous

transmission on two channels.
PRO-2RE-1PM-12V-...-TNC units are interconnected via a data cable for

mutual control.

ORDERING DESIGNATIONS

TYPE

PRODUCT NO.

FREQUENCY RANGE

PRO-2REL-1PM-12V-L-TNC

210001814

68 - 175 MHz

PRO-2REL-1PM-12V-H-TNC

210001448

300 - 470 MHz

SPECIFICATIONS

ELECTRICAL

MODEL

PRO-2REL-1PM-12V-...-TNC

TYPE

Relay

FREQUENCY RANGE

68 - 175 MHz or 300 - 470 MHz

SUPPLY VOLTAGE DC

11.5 V to 15 V

CURRENT

200 mA

POWER OPERATIONS RANGE

Min. 2 W Max. 40 W

INSERTION LOSS

< 0.5 dB

ISOLATION

>50 dB

SWR

< 1.5

SHIFT TIME

< 5 ms

OPERATIONS

10

7

MECHANICAL

CONNECTORS

TNC

DIMENSIONS (L x W x H)

90 x 77 x 28 mm/ 3.54 x 3.03 x 1.10 in.

(incl. connectors)

WEIGHT

Approx. 150 g/ 0.33 lb.

PROCOM A/S reserve the right to amend specifications