BRF 4/...-125

Band-Reject Filters for the 80 MHz Band

DESCRIPTION

High power base station band-reject filters for the 66 – 88 MHz range.
The use of large ø125 mm cavities means a high Q, resulting in a very

narrow notch bandwidth.
The large dimensions also mean a high power rating.
Unloaded Q of a single cavity is approx. 4500.
High frequency stability on temperature and power.
19” mounting brackets are available as an option.

ORDERING DESIGNATIONS

TYPE

PRODUCT NO.

BRF 4/1-125

200001918

BRF 4/2-125

200001919

BRF 4/3-125

200001211

SPECIFICATIONS

ELECTRICAL

MODEL

BRF 4/1-125

BRF 4/2-125

BRF 4/3-125

FREQ.

RANGE

66 - 88 MHz

66 - 88 MHz

66 - 88 MHz

MAX.

INPUT

POWER

300 W @

0.5 dB IL

175 W @

1.0 dB IL

300 W @

1.0 dB IL

175 W @

2.0 dB IL

300 W @

1.5 dB IL

175 W @

3.0 dB IL

1 dB NOTCH

BANDWIDTH

1 ‰ of f

c

1 ‰ of f

c

1 ‰ of f

c

IMPEDANCE

Nom. 50 Ω

Nom. 50 Ω

Nom. 50 Ω

SWR

(at resonance)

≤ 1.5

≤ 1.5

≤ 1.5

MECHANICAL

TEMP.

RANGE

RH 0-90% non-

condensing

–30° C →

+60° C

–30° C →

+60° C

–30° C →

+60° C

FREQ.

STABILITY

Approx. 1.5

ppm/° C

Approx. 1.5

ppm/° C

Approx. 1.5

ppm/° C

CONNECTORS

N-female

N-female

N-female

DIMENSIONS

ø125 x

1200 mm

L:125 x W:250 x

H:1200 mm

L:125 x W:375 x

H:1200 mm

WEIGHT

Approx.

4.3 kg

Approx.

8.9 kg

Approx.

13.5 kg

PROCOM A/S reserve the right to amend specifications

without prior notice.
29/03/11