Wp2p repeater module – QTech Data Systems Wireless Point to Point (WP2P) - Digital I__O User Manual

Page 3

Advertising
background image

Wireless Point to Point - DIGITAL – Quick Start Guide – v2.1 – June 2013

3

www.qtech.co.nz

Tel: 03 3663713

WP2P Repeater Module

A WP2P Repeater Module is available to increase the range and coverage of a WP2P
system. It is used in situations where the WP2P modules are a long way apart or there is an
obstacle preventing line-of-sight between them.

The WP2P Repeater Module operates by listening for complete and valid WP2P messages
and then re-transmitting them. It can be used with both WP2P DIGITAL and WP2P DIGITAL
& ANALOGUE type modules simultaneously.

Please refer to the Repeater Quick Start Guide for further details.

Power Supply Notes

Power Supply & Current Consumption
The WP2P operates from a nominal 12 Volt DC power supply.
Current consumption is ~32mA in standby (no output relays active) to 49/66/83mA (one, two
or three relays active).
The power connector is a 2.1mm DC Socket, centre pin positive. The supply voltage should
be clean, continuous and transient free with an output of 12 Volts +/- 1.5 Volt DC. The WP2P
incorporates reverse and overvoltage protection.
The absolute maximum supply voltage is 13.8 V DC and any solar/battery design needs to
take this into account.

Warning – Do NOT use Switch Mode Power Supplies (SMPS) with this product. The

DC power supply used for this product MUST have a grounded negative or be a
“linear” transformer based plug pack. The reason is that the aerial, programming port
and external connections can provide exposed earth points and the SMPS can impose
an AC voltage on the DC ground, which can lead to damage. Suitable cost effective
plug packs are available from QTech P/N PD5412, PD5413 & PD5414.

Internal Fuse
The WP2P module circuit is protected by a 20mm x 5mm 500mA fast blow fuse. This is
located on the internal circuit board. To access the fuse, remove the top cover by prizing it off
its retaining dimples. Only replace the fuse with an identical type, do not use alternatives.
This fuse will blow if the power supply maximum voltage is exceeded.

Over Voltage Protection
The WP2P module is over voltage protected by a 13 volt Zener Diode ‘crow bar’ that will
conduct and blow the internal fuse for voltages >14 volts. The WP2P will tolerate 13.8 volts,
but will begin to draw excessive current and blow the fuse at input voltages >14.6V.

Note – Solar Supplies and design considerations

Before using any WP2P module in a solar powered system please check our “Solar
Application Note” on our website. Explicit consideration must be given to the
maximum voltage and voltage regulation to prevent damage.

Advertising