the cooker hood must be at least 45 cm. If a connection tube

composed of two parts is used, the upper part must be placed

outside the lower part. Do not connect the cooker hood ex-

haust to the same conductor used to circulate hot air or for

evacuating fumes from other appliances generated by other

than an electrical source. Before proceeding with the assembly

operations, remove the anti-grease filter(s) (Fig.2.2 - Fig.3.2)

so that the unit is easier to handle.

- In the case of assembly of the appliance in the suction version

prepare the hole for evacuation of the air.

We recommend the use of an air exhaust tube which has the

same diameter as the air exhaust outlet hole. If a pipe with

a smaller diameter is used, the efficiency of the product may

be reduced and its operation may become noisier.

If the appliance is supplied with the small cupola M remove

it by releasing it as indicated in Fig.2.3 - Fig.3.3.

Before proceeding with the assembly operations, for easier

manoeuvrability of the appliance disengage the anti-grease

filter by pulling handle B as indicated in Fig.2.2 - Fig.3.2.

If one owns a model with perimeter suction panel, before

carrying out this operation, perform the following phases:

- Open panel C as indicated in Fig.2.1 - Fig.3.1.

- If one owns the version with three A panels release them

from the fixing pins by pulling outwards (Fig.3.4) and then

remove them from safety pins N (Fig.3.4) placed inside the

hood. To put them back perform the operation in reverse

order. ATTENTION! During this disassembly and assembly

operation ensure to hold the panel securely to prevent

accidental falls.

• Wall mounting:

Trace the bottom side of the hood on the wall. Consider the

measurements shown in Fig.4A and minimum distance from

the cooking surface (Fig.4B).

- Position the fixing template on the wall, making sure that

the line coincides with the line previously made on the wall.

- Mark the fixing holes and cut them into the material (Fig.5).

- Fix the 2 top screws K and screw anchors (Fig.5), without

tightening them completely.

- Position the appliance at the wall (Fig.6A).

- Make sure the 2 levelling screws J are tightened (Fig.6B.1).

- Align the appliance horizontally using the two levelling

screws J (Fig.6B.1).

- Once the adjustment has been made, fasten the hood

permanently using the screws K (Fig.6C - Fig.6D).

- For easy accessibility to the motor unit in the case of

assistance, after having levelled and fixed the appliance

definitively, we recommend that the brackets are removed

(Fig.6B.1).

- When carrying out the fixing operations, use only screws

and screw anchors suited to the type of wall (e.g. reinforced

concrete, plasterboard etc.).

- If the screws and screw anchors are supplied with the

appliance, make sure that they are suited to the type of wall

to which the hood must be fixed.

• Installation of models without decorative ducts:

Extractor hood

- Unclip the canopy M and remove the grille E (Fig.7).

- Pass the power supply cable through the slot in the canopy

M, as indicated in Fig.9A.1.

- Taking the grommet H, position it between the power cable

and the slot (Fig.9A.2).

- Connect the flexible hose L (not supplied) to the hood

(Fig.9B).

- Re-position the small cupola M paying attention that it is

hitched perfectly to the fixing pins G (Fig.9B).

• Filtering version:

- Unclip the canopy M and remove the grille E (Fig.7).

- Pass the power supply cable through the slot in the canopy

M, as indicated in Fig.8.1.

- Taking the grommet H, position it between the power cable

and the slot (Fig.8.2).

- Fix the small cupola M and the grille E making sure that is it

perfectly hooked on to the fastening pins G (Fig.8).

• Optional accessories:

This model may have decorative ducts as optional accessories

- ask your retailer for information.

Before installing decorative flues it is necessary to remove

the small cupola M and loosen the 4 screws Q that lock the

fastening pins G as shown in Fig.11.

• Installation of models with decorative ducts:

Extractor hood

Make sure the electrical power supply is within the

measurements of the decorative connector. Adjust the width

of the support bracket of the top connector (Fig.10.2).

Then fix it to the ceiling so that it is on the same axis as the

hood using screws A and observing the distance from the

ceiling shown in Fig.10.1.

Connect flange F to the air exhaust hole using flexible hose

L (Fig.12A).

Slide the top connector inside the lower duct and place this on

the body (Fig.12B). Pull out the top duct as far as the bracket

and secure it using screws B (Fig.10.2).

To transform the hood from a ducting version into a filtering

version, ask your dealer for the charcoal filters and follow the

installation instructions.

• Filter hood:

Please note:

The filters must be ordered from your dealer as an

accessory.

- To transform the hood from the SUCTION version to the

FILTERING version, charcoal filters must be ordered from your

dealer as an accessory.

Two types of kit are available, one with non-renewable filters

(Fig.13) and the other with renewable filters (washable)

(Fig.14). Unlike traditional carbon filters, this carbon filter can

be washed and reactivated for approximately 12-15 times.

With normal hood use, this filter should be cleaned once

every 2-3 months. The filter can be washed into a dishwasher

at the highest temperature using a standard dishwasher

detergent. After washing, dry the filter in the oven at 100°

C for 10-15 minutes to reactivate it. The filter will retain its

odour-absorbing capacity for three years, after which it will

have to be replaced.

- If a bracket is found in the packaging like that indicated in

Fig.14 loosen the screws already installed inside the hood and

install the bracket using the previously-removed screws.

- To replace re-usable carbon filters Y, remove the brackets

from their seat, pulling them outwards (Fig.14).

- If your product is not supplied with the bracket, it means

that the active charcoal filter cannot be renewed (Fig.13).

These must be applied to the suction unit inside the hood,

centring them in it and turning them 90° until they snap into

place (Fig.13).

- 26 -