UniFil Bond Technical manual version 1.10, November 2005,

22/23

10.0 Instructions for use

For use only by a dental professional in the recommended indications.


RECOMMENDED INDICATIONS

Bonding of light cured composites to tooth structure.


CONTRAINDICATIONS

1. Pulp capping.
2. In rare cases the product may cause sensitivity in some people. If any such

reactions are experienced, discontinue the use of the product and refer to a
physician.


DIRECTIONS FOR USE
1. CAVITY PREPARATION

Prepare tooth in usual manner. Dry the prepared tooth surfaces by gently blowing

with an air syringe.


Note: For pulp capping, use calcium hydroxide.


2. APPLICATION OF UniFil

®

Bond SELF-ETCHING PRIMER

Dispense 1 or 2 drops of UniFil

®

Bond SELF ETCHING PRIMER into the dispensing

dish provided. Apply the primer to the enamel and dentin surfaces on the
prepared tooth using a pink disposable micro-tip applicator provided, leave

undisturbed for 20 seconds.

Note:
1) Prior to use, leave the primer bottle at room temperature for 5 minutes after

removing from refrigerator.

2) After dispensing, use as quickly as possible.

3) Do not allow the primer to contact oral tissues. In case of contact,

immediately remove with a sponge or cotton. Rinse thoroughly with water

after placing composite.

4) Replace bottle cap immediately after use.


3. DRYING THE SELF-ETCHING PRIMER

20 seconds after application, gently dry with an air syringe for 5 seconds and
ensure that the primed surface has a glossy appearance. Do not rinse away.


Note: Should the applied Primer be rinsed away, dry the cavity and re-apply

primer.

4. APPLICATION OF UniFil

®

Bond BONDING AGENT

Dispense 1 or 2 drops of UniFil

®

Bond BONDING AGENT into the dispensing dish.

Immediately apply to the primed enamel and dentin surfaces using a yellow

colored micro-tip applicator. Blow gently with an air syringe to form a thin film.

Note:
1) Prior to use, leave the bottle of Bonding agent at room temperature for 5

minutes after removing from refrigerator.

Advertising