Initialization/Functional Restriction Setting (FUNCTION) menu

Function

Command

Direction

Parameter

Reply

Control/Response contents

*

ALL RESET

RSET

W

0

-

ADJUSTMENT LOCK

ALCK

WR

0-2

0-2 0: OFF, 1:ON 1, 2:ON 2

º

OSD DISPLAY

LOSD

WR

0-2

0-2 0: ON 1, 1: OFF, 2: ON 2

º

LED

OFLD

WR

0-1

0-1 0: ON, 1: OFF

º

TEMPERATURE ALERT

TALT

WR

0-2

0-2 0: OFF, 1: OSD & LED, 2: LED

º

STATUS ALERT

SALT

WR

0-2

0-2 0: OFF, 1: OSD & LED, 2: LED

º

Others

Function

Command

Direction

Parameter

Reply

Control/Response contents

*

VOLUME

VOLM

WR

0-31

0-31

º

BRIGHT

VLMP

WR

0-31

0-31

º

TEMPERATURE SENSOR

DSTA

R

0 Internal temperature normal

1 Internal temperature abnormal has occurred and the monitor is in standby

mode

2 Internal temperature abnormal occurred (To delete the information of

temperature abnormal, turn off the main power.)

3 Internal temperature abnormal has occurred and backlight brightness is

dimmed

4 Temperature sensor abnormal

TEMPERATURE ACQUISITION

ERRT

R

Value Returns the temperature of the temperature sensor.

Indicates a temperature sensor abnormality when “126” is returned.

º

CAUSE OF LAST STANDBY MODE

STCA

W

0

Initialization

R

0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature

20 Standby mode by OFF IF NO OPERATION setting

Controlling the Monitor with a PC (RS-232C)