Chapter 5 – Asus P8Z77-V PREMIUM User Manual

Page 169

Advertising
background image

ASUS P8Z77-V PREMIUM

5-9

Chapter 5

4.

Use the up or down arrow key to move the selection bar and press <Enter> to

configure further RAID settings.

RAID Level: Select a RAID Level. Configuration options: [RAID 0] [RAID 1]

Stripe Size: Specifies the size of single data block on the virtual disk. In general, a

larger stripe size is recommended for applications requiring large data transfers such

as audio, video, and graphics. A smaller stripe size is better for applications with

content in much smaller size, such as e-mails and documents.

Configuration options: [32K] [64K]

Gigabyte Rounding: In the event of a single physical disk failure in a RAID 1 virtual

disk, Gigabyte Rounding allows the replacement physical disk to be of a size slightly

smaller than the existing physical disk. The capacity of the rebuilt virtual disk equals

to the size of the smaller physical disk included in the RAID 1 array. The configuration

options represent the tolerance value of drive capacity difference.

Configuration options: [None] [1G] [10G]

Name: Enter a name with 1–10 letters (no special characters) for the RAID array.

5.

Move the selection bar to Next and press <Enter>. The following warning message

appears:

Do you want to create this virtual disk ?

Y

es

N

o

Create Virtual Disk

Press <Y> to create the RAID array, or press <N> to cancel. The new RAID array

appears under Virtual Disks, as shown in the image below.

Marvell BIOS Setup (c) 2009 Marvell Technology Group Ltd.

Help

Marvell RAID on chip controller.

ENTER: Operation F10: Exit/Save ESC: Return

HBA 0: Marvell 0

Virtual Disks

VD 0: New_VD
PD 0: ST3160812AS
PD 8: ST3160812AS

Free Physical Disks

Vendor ID :
Device ID :
Revision ID :
BIOS Version :
Firmware Version:
PCIe Speed Rate :
Configure SATA as:

Topology

Information

1B4B
9130
B1
1.0.0.1028
2.2.0.1105
5.0Gbps
AHCI Mode

Advertising