Hotpoint Ariston PO 740 ES (IX)-HA User Manual

Page 15

Advertising
background image

GB

15

Connection with a rigid pipe (copper or steel)
 Connection to the gas system must be carried out in

such a way as not to place any strain of any kind on the

appliance.

There is an adjustable LLLLL-shaped pipe fitting on the

appliance supply ramp and this is fitted with a seal in order

to prevent leaks. The seal must always be replaced after

rotating the pipe fitting (seal provided with appliance). The

gas supply pipe fitting is a threaded 1/2 gas cylindrical

male attachment.
Connecting a flexible jointless stainless steel pipe to a

threaded attachment
The gas supply pipe fitting is a threaded 1/2 gas

cylindrical male attachment.

These pipes must be installed so that they are never longer

than 2000 mm when fully extended. Once connection has

been carried out, make sure that the flexible metal pipe

does not touch any moving parts and is not compressed.
 Only use pipes and seals that comply with current national

regulations.
Checking the tightness of the connection
 When the installation process is complete, check the pipe

fittings for leaks using a soapy solution. Never use a flame.
Adapting to different types of gas
To adapt the hob to a different type of gas other than default

type (indicated on the rating plate at the base of the hob or

on the packaging), the burner nozzles should be replaced

as follows:
1. Remove the hob grids and slide the burners off their

seats.

2. Unscrew the nozzles using a 7 mm socket spanner, and

replace them with nozzles for the new type of gas (see

table 1 “Burner and nozzle characteristics”).

3. Reassemble the parts following the above procedure in

the reverse order.

4. Once this procedure is finished, replace the old rating

sticker with one indicating the new type of gas used.

Sticker are available from any of our Service Centres.

• Adjusting the burners’ primary air :
Does not require adjusting.

• Setting the burners to minimum:
1. Turn the tap to the low flame position.
2. Remove the knob and adjust the adjustment screw,

which is positioned in or next to the tap pin, until the

flame is small but steady.

3. Having adjusted the flame to the required low setting,

while the burner is alight, quickly change the position of

the knob from minimum to maximum and vice versa

several times, checking that the flame does not go out.

4. Some appliances have a safety device (thermocouple)

fitted. If the device fails to work when the burners are set

to the low flame setting, increase this low flame setting

using the adjusting screw.

5. Once the adjustment has been made, replace the seals

on the by-passes using sealing wax or a similar

substance.

 If the appliance is connected to liquid gas, the regulation

screw must be fastened as tightly as possible.
 Once this procedure is finished, replace the old rating

sticker with one indicating the new type of gas used.

Stickers are available from any of our Service Centres.
 Should the gas pressure used be different (or vary slightly)

from the recommended pressure, a suitable pressure

regulator must be fitted to the inlet pipe (in order to

comply with current national regulations).

DATA PLATE

Electrical

connections

220-240V ~ 50/60Hz

This appliance conforms to the

following European Economic

Community directives:

-73/23/EEC dated 19/02/73 (Low

Voltage) and subsequent

amendments

- 89/336/EEC dated 03/05/89

(Electromagnetic Compatibility)

and subsequent amendments

- 93/68/EEC dated 22/07/93 and

subsequent amendments.

- 90/336/EEC dated 29/06/90

(Gas) and subsequent

amendments.

- 2002/96/EC

Advertising