Burner and nozzle specifications – Hotpoint Ariston PC 730 RT GH-HA User Manual

Page 18

Advertising
background image

GB

18

Table 1 Liquid Gas Natural Gas

Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow*
power power 1/100 1/100 (g/h) power 1/100 (l/h)
kW kW kW
(p.c.s.*) (p.c.s.*) (p.c.s.*)
(mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)

Supply pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20
17
25

Fast (R)

Reduced Fast (RR)

Semi Fast (S)

Auxiliary (A)

Triple Crown (TC)

Ultrarapid (UR)

Semi-Fishburner (SP)

Double Flame
(DCDR Internal)

Double Flame
(DCDR External)
2 nozzle

100

100

75

55

130

100

30

130

0.70

0.70

0.40

0.40

1.50

0.70

0.70

0.40

1.50

3.00

2.60

1.65

1.00

3.30

3.40

1.50

0.90

4.10

39

39

28

28

61

39

39

28

61

86

80

64

50

65x2

91

60

44

70x2

218

189

120

73

240

247

109

65

298

214

186

118

71

236

243

107

64

293

3.00

2.60

1.65

1.00

3.30

3.40

1.50

0.90

4.10

116

110 (Y)

96

79

99x2

123

88

70

114x2

286

248

157

95

314

324

143

86

390

Burner and nozzle specifications

*

At 15°C and 1013 mbar - dry gas

**

Propane P.C.S. = 50.37 MJ/Kg

***

Butane P.C.S. = 49.47 MJ/Kg

Natural P.C.S. = 37.78 MJ/m³

! If the appliance is connected to liquid gas, the regulation
screw must be fastened as tightly as possible.
! Once this procedure is finished, replace the old rating
sticker with one indicating the new type of gas used.
Stickers are available from any of our Service Centres.
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet pipe (in order
to comply with current national regulations).