SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR

MAJOR PROPERTY DAMAGE, READ AND FOLLOW ALL

SAFETY INSTRUCTIONS IN MANUAL AND ON PUMP.

This is a SAFETY ALERT SYMBOL. When

you see this symbol on the pump or in the

manual, look for one of the following signal

words and be alert to the potential for per-

sonal injury or property damage.
Warns of hazards that WILL cause serious

personal injury, death or major property

damage.
Warns of hazards that CAN cause serious

personal injury, death or major property

damage.
Warns of hazards that CAN cause personal

injury or property damage.

NOTICE: INDICATES SPECIAL INSTRUCTIONS

WHICH ARE VERY IMPORTANT AND

MUST BE FOLLOWED.

THIS MANUAL IS INTENDED TO ASSIST IN THE

INSTALLATION AND OPERATION OF THIS UNIT

AND MUST BE KEPT WITH THE PUMP.
MAINTAIN ALL SAFETY DECALS.

UNIT NOT DESIGNED FOR USE

WITH HAZARDOUS LIQUIDS OR

FLAMMABLE GASES.

NOTICE: INSPECT UNIT FOR DAMAGE AND

REPORT ALL DAMAGE TO THE CARRIER

OR DEALER IMMEDIATELY. DO NOT USE

PUMP IF DAMAGE IS SUSPECTED.

DESCRIPTION AND SPECIFICATIONS

• The SPM/SPH Series embraces a line of end suction single

stage, self-priming centrifugal pumps for lawn

sprinkling, HVAC systems, and general water transfer.

• Casing is cast iron construction with tapped openings

provided for vacuum gauge and casing drain.

• Impeller is bronze, enclosed design, balanced for smooth

operation and keyed to motor shaft.

• ALL motors are NEMA standard, 3500 RPM, open drip

proof or TEFC enclosure.

DANGER

WARNING

WARNING

Hazardous fluids

can cause fire,

burns or death.

ENGINEERING DATA

Prime Line SP Data

Model

Suction Impeller

HP

Discharge Phase/Hz

Flange Size

SPH130

SPF20A 5.94

3 1½

1/60

SPH330

3/60

SPM130

SPF25A 5.06

3

2

1/60

SMP330

3/60

SPH150

SPF25A 6.19

5

2

1/60

SPH350

3/60

SPM150

SPF30A

5.82 5 2½

1/60

SPM350

3/60

Table 1

• Maximum Liquid Temperature: 160º F (71º C)
• Starts per hour: 20 – evenly distributed.

PIPING

• Pump MUST be installed horizontally on a solid flat surface,

with discharge on top.

• Allow adequate space for servicing and ventilation. Protect

the unit from weather and water damage due to rain or

flooding or freezing temperatures.

• Piping should be no smaller than the suction and discharge

connections and kept as short as possible, avoiding unneces-

sary fittings to minimize friction losses. See Table 1.

• All piping MUST be independently supported and MUST

NOT place any piping loads on the pump.

NOTICE: DO NOT FORCE PIPING INTO PLACE AT

PUMP SUCTION AND DISCHARGE

CONNECTIONS.
• The use of Teflon™ tape, or equivalent, is recommended for

ALL pipe joints.

• All pipe joints MUST be airtight.
PIPING – SUCTION
• Total suction lift, including elevation and pipe friction loss,

should not exceed 25 feet.

• Install an airtight union in the suction line close to the pump.

See Figure 1.

Figure 1

PRIMING

OPENING

FUSED OR

CIRCUIT BREAKER

DISCONNECT MEANS

DISCHARGE

SUCTION

UNION

CAUTION

DESCRIPTION AND SPECIFICATIONS

ENGINEERING DATA

PIPING