DANGER

WARNING

CAUTION

Hazardous machinery

can cause personal

injury or death.

WARNING

Hazardous fluids can

cause personal injury

or property damage.

WARNING

SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL

INJURY OR MAJOR PROPERTY DAMAGE, READ

AND FOLLOW ALL SAFETY INSTRUCTIONS IN

MANUAL AND ON PUMP.

This is a SAFETY ALERT SYMBOL.

When you see this symbol on the pump or

in the manual, look for one of the follow-

ing signal words and be alert to the poten-

tial for personal injury or property damage.
Warns of hazards that WILL cause serious

personal injury, death or major property

damage.
Warns of hazards that CAN cause serious

personal injury, death or major property

damage.
Warns of hazards that CAN cause personal

injury or property damage.

NOTICE: INDICATES SPECIAL INSTRUCTIONS

WHICH ARE VERY IMPORTANT AND

MUST BE FOLLOWED.

THOROUGHLY REVIEW ALL INSTRUCTIONS

AND WARNINGS PRIOR TO PERFORMING ANY

WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.

FAILURE TO DISCONNECT AND

LOCKOUT ELECTRICAL POWER BE-

FORE ATTEMPTING MAINTENANCE

CAN CAUSE SEVERE PERSONAL IN-

JURY.

IF PUMPING HAZARDOUS OR TOXIC

FLUIDS, SYSTEM MUST BE FLUSHED

PRIOR TO PERFORMING SERVICE.

PUMP STACK REMOVAL

1. Close all necessary suction and discharge valves.

2. Drain the liquid from the pump by removing the lower

drain plug and the upper vent plug.

3. Remove the coupling guards, the 4 coupling hex cap

screws, the coupling and coupling drive pin.

4. Remove the 4 motor hex cap screws. *On 33-125SV

units with motor frames 213TC and larger and

1-22SV units with motor frames 280TC and larger,

remove the 4 motor adapter flange hex cap screws.

5. With an adequately sized crane, carefully remove the

motor. DO NOT rest the motor on the motor shaft.

6. Remove Seal Gland or Cartridge Seal

• For 1-22SV units, remove the 4 socket head cap

screws to lift and remove the seal gland.

• For 33-125SV units without cartridge seal;

1. Remove the 4 socket head cap screws.
2. Lift and remove the seal gland. If seal gland

does not lift by hand, use the two tapped holes

provided to loosen and lift the gland for removal.

• For 33-125SV units with cartridge seal;

1. Loosen the 4 set-screws located around the ID of

the pump shaft.

2. Remove the 4 socket head cap screws.
3. Remove the cartridge seal using the two tapped

holes provided on the gland of the cartridge seal

by threading two of the hex cap screws into these

holes and evenly tightening these screws..

4. Once loosened, lift and remove the cartridge seal.

7. Remove the 4 tie rod nuts and washers.

8. Remove Motor Adapter / Motor adapter assembly and

upper seal plate

• For 1-22SV units lift the motor adapter to remove.

*Note that the upper seal plate may remove with the

motor adapter when lifting. If the upper seal plate

remains on the pump casing, lift to remove.

• For 33-125SV units, lift the motor adapter assembly

(motor adapter and top seal plate). A crane may be

required to safely lift the motor adapter assembly.

9. Remove the pump stack, grasp the pump shaft, rock

side to side to free the stack, then lift vertically. If the

first stage bowl remained in the pump body, CARE-

FULLY pry up the bowl and remove.