Instructions for licensed electricians, Pump parts list – Xylem AC1683B Marlow Series Cast Iron Swimming Pool Pumps 3B28EC – 3B32EC User Manual
Page 5
![background image](/manuals/310364/5/background.png)
INSTRUCTIONS FOR
LICENSED ELECTRICIANS
The wire used to supply power to the motor must be large
enough to carry the necessary amperes for the required
length without excessive voltage drop.
5
Key
Description
*
1
Hand
Knob
s
2
Cover
*
3
Gasket,
Cover
*
4
Strainer Basket
5
Strainer
Body
6
Drain Plug
*
7
Gasket, Body
8
Tank
11
Filler Plug
12
Tank Strainer Comb.
13
Cap Screw
* 14
Gasket, Diffuser
s 15
Diffuser
* 16
Impeller Bolt
* 17
Impeller Lockwasher
* 18
Impeller Washer
s 19
Impeller, Closed
s 20
Impeller, Open
* 21
Impeller
Shim,
F/C.I.
Impellers
* 22
Seal Assembly
* 23
Gasket,
Tank
24
Lantern
WARNING
All electric work must be done by a licensed
electrician. Before working on motors be certain that the
electrical power is off at the main junction box.
Disconnect the fuse or the circuit breaker and tag the
main switch: “Do not energize this switch. Personnel
working on equipment.” Failure to follow these instruc-
tions may result in personal injury, death or property
damage.
PUMP PARTS LIST
See Page 6 For Exploded View Illustration
* Recommended Spare Parts.
s Recommended Distributor Stock, Export Spares and Critical Service.
Key
Description
25
Cap Screw
* 26
Slinger
* 27
Shim
28
Motor
29
Hex Nut
30
Foot
31
Lantern-Motor Comb.
32
Yoke
33
Stud
* 34
Impeller Key
* 35
Shaft Sleeve
36
Suction Inlet
37
Carriage Bolt
38
Gasket, Bolt
39
Lower Weight
40
Valve Facing
41
Upper Weight
42
Stop Plate
43
Lockwasher
44
Hex
Nut
* 45
Check Valve Assembly
Be sure the motor is properly wired to match the voltage and
phase of the power supply line. On three-phase motors be