Xylem HYDROQSG Hydrovar Quick Start Guide User Manual

Page 2

Advertising
background image

100

SUBMENU

BASIC SETTINGS

200

SUBMENU

C

ONF INVER

TER

300

SUBMENU

REGULA

TION

400

SUBMENU

SENSOR

500

SUBMENU

SEQUENCE CNTR

100

SUBMENU

BASIC SETTINGS

60

SUBMENU

SETTINGS

200

SUBMENU

C

ONF INVER

TER

300

SUBMENU

REGULA

TION

400

SUBMENU

SENSOR

500

SUBMENU

SEQUENCE CNTR

61

PASSW

ORD

0000

105

MODE

C

ontr

oller

202

SOFTW

ARE

HV

V01.3

205

MAX.

UNITS

6

210

INVER

TER

ALL

215

RAMP 1

4 sec

225

RAMP 3

70 sec

260

FMIN TIME

0 sec

265

BOOS

T

5 %

310

WINDOW

10 %

510

A

CT

.V

AL.DEC

2 PSI

540

DROP FREQ

42.0 Hz

410

C

ONF

SENSOR

Sensor 1

315

HYS

TERESIS

80 %

515

ENABLE FREQ

48 Hz

545

O

VER

VAL

UE

disabled

415

SENSOR T

YPE

analog I 4-20mA

320

REG.

MODE

normal

520

ENABLE DL

Y

5 sec

550

O

VER

VAL

DL

Y

0 sec

420

SENS.

RANGE

300 PSI

325

FRQ.

LIFT

30.0 Hz

525

SWIT

CH DL

Y

2 sec

555

SWIT

CH INTV

24 hours

425

SENS.

CUR

VE

line

ar

330

LIFT

AMOUNT

0.0 %

530

DISABLE

FRQ

30.0 Hz

560

S

YNCH.LIM.

0.0 Hz

565

S

YNCH.

WIN.

2 Hz

570

MS

TPRIORIT

Y

ON

430

SENS1 C

AL

0

0 % = x,xx PSI

440

SENS2 C

AL

0

0 % = x,xx PSI

435

SENS1

CAL

X

0 % = xx,xx PSI

445

SENS2

CAL

X

0 % = xx,xx PSI

285

SKIPFRQ C

TR

0.0 Hz

270

KNEE

FREQ.

60 Hz

286

SKIPFRQ

RNG

60 Hz

275

POWER RED

.

OFF

290

CURR.

LIMIT

OFF

280

SEL.SW

.FRQ.

Auto

291

CURR.

LIMIT

100 %

230

RAMP 4

70 sec

235

RAMP

FMIN

A

2 sec

240

RAMP FMIN D

2 sec

245

MAX.

FREQ

60 Hz

250

MIN.

FREQ

20 Hz

220

RAMP 2

4 sec

203

SET

VER

INV

sel.

01

act.

01

106

PUMP

ADDR

1

110

SET

P

ASSW

.

0066

115

LOCK

FUNC

T.

0066

120

DISP

. C

ONTR.

75 %

125

DISP

. BRIGHT

100 %

62

JOG

Hz

50 PSI

305

JOG

Hz

50 PSI

505

A

CT

.V

AL.INC

5 PSI

535

DISABLE DL

Y

5 sec

405

DIMENS.

UNIT

PSI

255

C

ONF

. FMIN

F > 0

1000

SUBMENU

TES

TRUN

800

SUBMENU

REQUIRED V

AL

UES

700

SUBMENU

OUTPUTS

1000

SUBMENU

TES

TRUN

1100

SUBMENU

SETUPS

1100

SUBMENU

SETUPS

605

MIN.

THRESH.

disabled

705

ANAL

OG OUT1

Output fr

equency

1005

TES

TRUN

100 hours

610

DELA

Y

TIME

2 sec

1010

TES

TRUN

FREQ.

30 Hz

710

ANAL

OG OUT2

Actual value

810

C.REQ.

V

AL.2

OFF

1120

P

ASSW

ORD 2

0000

907

OFFS.INPUT

100

1210

BA

UDRA

TE

9600

1215

FORMA

T

R

TU N81

830

A

C

TU

A

T.FRQ1

0.0 Hz

1220

PUMP ADDR

1

835

A

C

TU

A

T.FRQ2

0.0 Hz

805

C.REQ.

V

AL.1

digital

1110

F

A

C

TOR

Y SET

USA

905

OFFS.INPUT

OFF

1205

ADDRESS

1

615

ERROR RESET

ON

1015

TES

TR.BOOS

T

10 %

715

C

ONF REL

1

R

unning

815

SW

REQ.

V

AL

Setpoint 1

1125

CLR ERRORS

ALL

910

LEVEL

1

0

915

LEVEL

2

100

1020

TES

TR.

TIME

5 sec

720

C

ONF REL

2

Err

ors

820

REQ.

V

AL.1

50 PSI

1130

CLR

MO

TORH.

ALL

912

OFFSET

X1

0

917

OFFSET

X2

100

1025

SEL.DEVICE

01

1030

TES

TRUN MAN

Pr

ess > 3 sec

825

REQ.

V

AL.2

50 PSI

1135

CLR OPERA

T.

Pr

ess > 3 sec

913

OFFSET

Y1

0 PSI

918

OFFSET

Y2

0 PSI

800

SUBMENU

REQUIRED V

AL

UES

600

SUBMENU

ERRORS

600

SUBMENU

ERRORS

700

SUBMENU

OUTPUTS

1200

SUBMENU

RS485-INTERF

A

CE

1200

SUBMENU

RS485-INTERF

A

CE

900

SUBMENU

OFFSET

900

SUBMENU

OFFSET