Xylem IM105R05 Sump Pumps User Manual

Page 3

Advertising
background image

3

in the area a bolt-on or child-proof cover is

recommended.

3. PIPING
3.1.
Discharge pipe should be the same size

as the pump discharge to insure optimum

performance. Using undersized pipe may

dramatically reduce the flow and therefore

waste energy. Your pump supplier can sug-

gest the correct pipe for your installation.

3.2. Install a threaded pipe adapter, matched

to the pipe type you are using, into the

threaded pump discharge. One end will have

a male thread and the other end will have

a barbed connector, compression fitting or

solvent weld connector. Use Teflon

®

tape on

all threaded joints. If using solvent welded

pipe and fittings it is best to dry fit them first

and after verifying the fit, solvent weld. A

union installed just above the sump or basin

cover will facilitate future maintenance and

replacement. See Chart 1 for discharge sizes.

3.3. Install a line check valve within 2 feet of

the pump. Install per valve manufacturer’s

instructions.

IMPORTANT - Drill a

1

8

" (3.2mm) relief hole

in the discharge line approximately 2” (51

mm) above the pump discharge connection

but below the check valve and within the

sump. This “relief ” hole allows trapped air

to escape from the pump and prevents air-

locking the pump. Failure to drill this hole

is a major cause of sump pumps failing to

pump after long periods of inactivity such as

seasonal use. Model ST is self-venting - no

hole is required.

4. INSTALLATION IN SUMP
4.1.
The pump can be placed directly on the

bottom of a poly or fiberglass sump basin

or a concrete sump bottom. If the bottom is

packed gravel the stones must be larger than

½” (13mm) in diameter and the pump

should be placed on bricks for support.

4.2. After connecting the discharge pipe to the

pump it can be lowered into the sump (ba-

sin). Always lower the pump by the handle

and the pipe, never by the power cord. Place

the pump against the basin wall so the switch

is to the center. See "Installation Data".

3. PIPING

4. INSTALLATION IN SUMP

1. GENERAL INFORMATION
1.1.
Sump pumps are designed to operate inter-

mittently and usually seasonally. It is recom-

mended that you test the pump before your

rainy season begins to insure that the pump

and switch are operating properly.

1.2. We suggest installing a high water alarm

system and a battery back-up pump system

for finished basements or areas where flood-

ing will cause property damage. A back-up

generator is another option you can discuss

with your pump installer. Most power out-

ages occur during rain storms, just when

you need your sump pump the most! Pump

manufacturer's warranties cover only the

pump. Labor and incidental damage such as

flooding is not covered.

2. PRE-INSTALLATION CHECKS
2.1.
Open all cartons and inspect for shipping

damage. Report any damage to your supplier

immediately.

2.2. Verify that all equipment is the correct volt-

age. Warranty does not cover damage caused

by connecting pumps and controls to incor-

rect voltage.

2.3. Is your basin sized correctly and the proper

type for the location?

Diameter - It must be wide enough to allow

the pump and switch to physically fit and

provide room for the switch to operate

freely. The vertical switch models typically

require less diameter than the wide-angle

float models. See "min. basin diameter" in

Chart 1.

Depth - It must be deeper

than the minimum depth at

which the switch turns the pump On. As an

example, if the pump turns on at 15" you

want to use a basin deeper than 15”.

See "On level" in Chart 1.

Style - There are several

sump basin styles available.

The location of the sump determines if you

require a cover and what type you require.

It is important to keep debris from entering

the sump and clogging the pump. An open

sump in a traffic area such as a basement is

dangerous. If children or pets will be playing

2. PRE-INSTALLATION CHECKS

1. GENERAL INFORMATION

WARNING

CAUTION

Advertising