Accessories / part numbers, Declaration of conformity – YSI Pro2030 User Manual

Page 24

Advertising
background image

40

41

A C C E S S o R I E S / PA R T N U M B E R S

Part Number

Description

6052030

Pro2030 Instrument

6262030-1, -4, -10, -20, or -30

1, 4, 10, 20, 30-meter cable assembly*

605202

Galvanic Dissolved oxygen Sensor

605203

Polarographic Dissolved oxygen Sensor

603077

Flow cell

603056

Flow cell mounting spike

603075

Carrying case, soft-sided

603074

Carrying case, hard-sided

603069

Belt clip

063517

Ultra clamp for instrument

063507

Tripod for instrument

603062

Cable management kit, included with all cables

longer then 1 meter.

605978

Cable weight, 4.9 oz, stackable

603070

Shoulder strap

605306

5908 membrane kit, yellow 1.25 polyethylene

for polarographic sensors

605307

5909 membrane kit, blue 2.0 polyethylene for

polarographic sensors

605913

5913 membrane kit, yellow 1.25 polyethylene

for galvanic sensors

605914

5914 membrane kit, blue 2.0 polyethylene for

galvanic sensors

060907

Conductivity Calibration Solution, 1,000 μS/

cm. 1 box of 8 pints.

060911

Conductivity Calibration Solution, 10,000 μS/

cm. 1 box of 8 pints.

060660

Conductivity Calibration Solution, 50,000 μS/

cm. 1 box of 8 pints.

065274

Conductivity Calibration Solution, 100,000 μS/

cm. 1 box of 8 pints.

*All cables include a temperature and conductivity sensor. The dissolved oxygen

sensor is sold separately.

D E C L A R A T I o N o F C o N F o R M I T Y

The undersigned hereby declares on behalf of the named manufacturer under our

sole responsibility that the listed product conforms to the requirements for the listed

European Council Directive(s) and carries the CE mark accordingly.

Manufacturer:

YSI Incorporated

1725 Brannum Lane

Yellow Springs, oH 45387

USA

Product Name:

Pro2030 Water Quality Instrument

Model Numbers
Instrument/Accessory:

Pro2030 (6052030)

Probe/Cable Assemblies: 6052030-1, -4, -10, -20, and -30
Conforms to the following:
Directives:

IEC 61326-1:2005

RoHS 2002/95/EC

WEEE 2002/96/EC

Harmonized Standards:

EN61326-1:2006 (IEC 61326-

1:2005) Emission & Immunity

Supplementary

Information:

All performance met the operation criteria as follows:

1. ESD, IEC 61000-4-2:2001, Performance Criterion B

2. Radiated Immunity, IEC 61000-4-3, Performance

Criterion A

3. Electrical Fast Transient (EFT), IEC

61000-4-4:2004, +Corr. 1:2006 + Corr.

2:2007, Performance Criterion B

4. Radio Frequency, Continuous Conducted

Immunity, IEC61000-4-6, Performance Criterion A

5. RF Emissions, EN 61326-1:2006

(IEC61326-1:2005) Class B

Authorized EU

Representative

YSI Hydrodata Ltd

Unit 2 Focal Point, Lacerta Court, Works Road

Letchworth, Hertfordshire, SG6 1Fj UK

Signed: Lisa M. Abel

Date: 07 july 2010

Title: Director of Quality